background image

GENERAL INFORMATION

This pump is only to be used for the purpose
of pumping air and under no circumstances
be used with any other gases. The pump
must not be used for the pumping of fluids,
particles, solids or any substance mixed
with air, particularly combustible substances
likely to cause explosions.

DANGER

Do not pump flammable or
explosive gases, or operate
the unit in an atmosphere
containing them without
appropriate motor and
electrical connection.

CAUTION

The exhaust air of this pump
can become very hot. Do
not direct exhaust air
towards property that is
temperature sensitive.

CAUTION

This pump is designed for air
only. Do not allow corrosive
gases or particulate material
to enter the pump. Water
vapor, oil-based contaminants,
or other liquids must be
filtered out.

Ambient temperature should not exceed
40°C (104°F). For operation at higher
temperatures, consult the factory.

Performance is reduced by lower
atmospheric pressure found at high
altitudes. Consult a Corken distributor
for details (see chart).

Never lubricate this oil-less air pump.
The sealed bearings are grease packed,
and the service life of the rings or vanes
will be reduced by petroleum or
hydrocarbon products.

INSTALLATION

WARNING

To avoid risk of
electrocution do not use
this product in an area
where it could come in
contact with water or other
liquids. If exposed to the
elements it must be
weather protected.

WARNING

Beware of any exposed
moveable parts. Proper
guards should be in place
to prevent personal injury
or death.

CAUTION

Do not block the flow of
cooling air over the pump in
any way.

CAUTION 

Do not lift the unit by the fan
shroud, filters or mufflers.

MOUNTING

This pump may be installed in any
orientation as long as the flow of cool,
ambient air over the pump is not blocked.
To reduce noise and vibration, mount to a
stable, rigid operating surface. If mounted
outside, cover or shield from the elements.

PLUMBING

To prevent air flow restriction, use pipe
and fittings that are the same size or
larger than the threaded ports of the
pump. The ports are marked "IN" and
"OUT”. Be sure to remove port plugs
before operating unit.

ACCESSORIES

Intake and exhaust filters are external to
the pump and will provide adequate
filtration for most applications. Check
filters periodically and replace when
necessary. Consult a Corken
representative for additional filter
recommendations. Install relief valves

Summary of Contents for Corken Coro-Vac CPS1V

Page 1: ...CPS1V CPS4V CPS6R IMPORT ANT INSTRUCTIONS OILLESS SERIES CORO VAC MODEL CYLINDER TANK PURGING SYSTEMS IG100...

Page 2: ...perly see the troubleshooting guide CYLINDER PURGING INSTRUCTIONS This Corken Coro Vac Cylinder Purge System may be used on multiple cylinders The following instructions apply regardless of the number...

Page 3: ...10 10 20 58 16 51 10 40 AIR CONTENT Container Evacuated to 2 psia Conatiner Evacuated to 5 psia Container Pressure Percentage Air Content Percentage Air Content psig 0 13 3 34 2 25 4 9 12 7 50 3 0 7 8...

Page 4: ...and the service life of the rings or vanes will be reduced by petroleum or hydrocarbon products INSTALLATION WARNING To avoid risk of electrocution do not use this product in an area where it could co...

Page 5: ...stood or if in doubt as to whether the product is properly grounded FOR ALL GROUNDED CORD CONNECTED PRODUCTS This product should be grounded In the event of an electrical short circuit grounding reduc...

Page 6: ...red severe personal injury of death can occur WARNING Always disconnect the power before servicing The motor may be thermally protected and will restart automatically when it cools if the thermal prot...

Page 7: ...S4X Remove the shroud cylinder head and valve components DO NOT re arrange the valve components Remove the cylinder and rings Make sure all parts are clean before reassembling DO NOT use any chlorinat...

Page 8: ...in its bore in the dead end plate Be careful to press only on the inner bearing race 9 Install and tighten the pump body bolts Install the belleville springs with the washer between them and the snap...

Page 9: ...p X X X Dirty Muffler X X X Plugged Vacuum Line X at pump X X Vanes Sticking X X Running at Too High RPM X X X X Rings Vanes Worn X X Shaft Seal Worn Replace X Particulate Material in Pump X X X X Mot...

Page 10: ...alve Outlet 1 7 Valve Plate 1 8 Valve Inlet 1 9 Cylinder Gasket 1 10 Cylinder 1 11 Piston Ring 2 12 Piston Seal 2 13 Rider Ring 1 14 Piston Rod Assembly 1 15 Counter Weight 1 16 Flat Key 1 17 Fan 1 18...

Page 11: ...ne Filter not shown 1 4 Cylinder Head 2 5 Head Gasket 2 6 Valve Outlet 2 7 Valve Plate 2 8 Valve Inlet 2 9 Cylinder Gasket 2 10 Cylinder 2 11 Piston Ring 4 12 Piston Seal 4 13 Piston Rod Assembly 2 14...

Page 12: ...uard 1 17 Intake Filter Assembly 1 18 Gasket 2 19 Jar 2 20 Filter Assembly 1 21 Cartridge 2 22 Filter Felt 1 23 Muffler 1 24 Muffler Assembly 1 25 Fan 1 26 Flange 1 27 Sleeve 1 28 Flange 1 29 Retainer...

Reviews: