Idex Blagdon Pump X75 Service And Operating Manual Download Page 3

x75mfvmdl2sm-rev0411 

Page 1 

INTAKE/DISCHARGE PIPE SIZE

HDF3-M: 3" 150# ANSI Flange

HDF4-M: 4" 150# ANSI Flange

CAPACITY

0 to 260 gallons per minute

(0 to 988 liters per minute)

AIR VALVE

No-lube, no-stall

design

SOLIDS-HANDLING

Up to nearly 3" 

(75mm)

HEADS UP TO

125 psi or 289 ft. of water

(8.8 Kg/cm

2

 or 88 meters)

Pumps are designed to be powered only by compressed air.

U.S. Gallons per minute

10

0

0

20

30

40

50

60

70

80

90

100

20

40

60

80

100 120 140 160 180 200 220 240 260

20(34)

60 PSI

40 PSI

40(68)

60(101.9)

80(135.9)

100(169.9)

120(203.9)

140(237.9)

160(271.8)

180(305.8)

20 PSI Air Inlet Pressure

100 PSI

80 PSI

Liters per minute

CAPACITY

0

100

200

300

400

500

600

700

800

900

1000

AIR CONSUMPTION 

SCFM (M

3

/hr)

PSI

BAR

HEAD

0

1

2

3

4

5

6

7

200(339.8)

MODEL HDF3-M /HDF4-M Performance Curve

Performance based on the following: elastomer fitted pump, flooded suction,

water at ambient conditions. The use of other materials and varying hydraulic

conditions may result in deviations in excess of 5%.

X75 Metallic Flap Valve Pump
Design Level 2

Air-Operated 

Double Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

II 2GD T5

See page 17

for ATEX ratings

Summary of Contents for Blagdon Pump X75

Page 1: ...ve Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair...

Page 2: ......

Page 3: ...34 60 PSI 40 PSI 40 68 60 101 9 80 135 9 100 169 9 120 203 9 140 237 9 160 271 8 180 305 8 20 PSI Air Inlet Pressure 100 PSI 80 PSI Liters per minute CAPACITY 0 100 200 300 400 500 600 700 800 900 100...

Page 4: ...Steel equal to or exceeding ASTM specification A743 for corrosion resistant iron chro mium iron chromium nickel and nickel based alloy castings for general applications Commonly referred to as 316 Sta...

Page 5: ...x75mfvmdl2sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Page 6: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Page 7: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Page 8: ...nd caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operati...

Page 9: ...l the outer diameter of one diaphragm off the 8 capscrews NOTE One side only On the free diaphragm assembly use a 3 8 allenwrenchtoturntheassembly diaphragm platesandscrew loosefromtheshaft Oncetheass...

Page 10: ...blems with the pilot valve can be corrected by replacing the o rings Always grease the spool prior to inserting it into the sleeve If the sleeve is removed from the body reinsertion must be at the cha...

Page 11: ...LE CAUSES A Discharge hose or line plugged or discharge head requirement greater than air supply pressure Disconnect discharge line to check B Spool in air distribution valve not shifting Remove end c...

Page 12: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Page 13: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Page 14: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Page 15: ...330 Capscrew Hex Head 8 17 095 043 010 Body Valve 1 18 196 100 015 Chamber Inner 2 19 560 022 360 O Ring 2 20 170 045 330 Capscrew Hex Head 4 21 530 036 000 Muffler Exhaust 1 22 685 041 120 Rod Diaphr...

Page 16: ...ischarge 2 59 518 045 010 Manifold 2 60 338 011 354 Flap Valve 4 338 011 356 Flap Valve 4 338 011 357 Flap Valve 4 338 008 360 Flap Valve 4 338 008 365 Flap Valve 4 61 570 002 360 4 570 002 365 4 62 1...

Page 17: ...x75mfvmdl2sm rev0411 Page 15 USE WITH HDF4 M ONLY...

Page 18: ...Technologies Ireland Ltd A Unit of IDEX Corporation R79 Shannon Co Clare IRELAND Certifies that Air Operated Double Diaphragm Pump B and X Series comply with the European Community Directive 2006 42...

Page 19: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Page 20: ...e Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair D...

Page 21: ......

Page 22: ...ed air II 2GD T5 See page 17 for ATEX ratings 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 PSI 20 PSI...

Page 23: ...Neoprene R Santoprene H Hytrel P Polyurethane Diaphragms B Nitrile R Santoprene N Neoprene Maximum delivery 998 ltrs min Max working pressure 8 6 bar Max solid particle size 75mm Air inlet 1 2 NPT Te...

Page 24: ...x75afvmdl7sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Page 25: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Page 26: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Page 27: ...s of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operation An...

Page 28: ...nutsandelbows Whenthetopsuctionelbows areremoved thevalveandseatareconnectedasanassembly Whenthebottomdischarge elbowsareremoved thevalveandseatstaywiththeouterchamber Visualinspectionand cleaning is...

Page 29: ...aining outer chamber on the open end and tighten down the securing nuts gradually and evenly on both sides Caution should be used while reassembling Flap valves The valves are designed for some preloa...

Page 30: ...not shifting Remove end cap and check spool must slide freely C Diaphragm ruptured Air will escape out discharge line in this case D Blockage in diaphragm chamber preventing movement Shut off air supp...

Page 31: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Page 32: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Page 33: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Page 34: ...W O RING 560 001 360 2 11 165 011 157 CAP END 2 12 170 012 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8 13 170 023 330 CAPSCREW HEX HEAD 4 14 170 024 330 CAPSCREW HEX HEAD 7 16 14 X 1 8 15 170 032 330 CA...

Page 35: ...360 O RING 2 40 570 002 360 PAD HINGE 4 570 002 365 PAD HINGE 4 41 570 012 371 PAD WEAR 2 42 612 014 000 PLATE DIAPHRAGM 2 43 612 015 156 PLATE OUTER DIAPHRAGM 2 44 618 003 330 PLUG PIPE 1 4 2 45 618...

Page 36: ...5 USE WITH HDF4 M ONLY 32 21 20 22 29 19 30 4 A 4 D 31 3 16 4 F 4 E 48 10 37 46 14 34 28 35 53 47 40 50 27 52 50 51 25 33 23 24 56 17 6 4 B 4 C 15 11 8 58 42 59 36 5 26 9 38 1 45 7 39 54 12 17 55 44 2...

Page 37: ...X Corporation R79 Shannon Co Clare Ireland Certifies that Air Operated Double Diaphragm Pump Series B75 X75 AVB75 AVX75 and Pulsation Dampener models PD25M PD40M PD50M PD80M comply with comply with th...

Page 38: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Reviews: