background image

pulse induction metal detector - 

impulse

2

 

Page 5 

 

Power consumption  

 

For correct display of battery icon please select the correct type of power 
source connection: 

- 3 LiION 

– connected in series of three Li-ION batteries.  

- Pb

– lead battery 12 Volts. 

- 10 NiMH

– connected in series of ten batteries type АА 1.2 Volts each. 

Do not connect to the device to any power source with more than 16 Volts! 
It may lead to the device malfunction. 

 

Filter 

 

When device is working with maximum sensitivity false actuations may 
occur.  

In order to decrease number of false actuations, please select one of four 
filters: 

0.  Filter is off 

– maximum sensitivity, but occurrence of false actuation is 

high. 

1.  Filter 

«1» - arithmetical average of the signal – sensitivity is good, 

possibility of false actuation is low. 

2.  Filter 

«2» - few responses values higher than threshold of 

subsequent ones 

– sensitivity excellent, possibility of false actuations 

is low. 

3.  Filter 

«3» - dynamic «reset» is useful in case of «drift» – sensitivity is 

average, possibility of false actuations is low. 

Summary of Contents for IMPULSE 2

Page 1: ...OPERATION MANUAL impulse2 pulse induction metal detector...

Page 2: ...nd other types of environment This metal detector makes no difference and able to detect all types of metals With this metal detector one can connect search devices coil of different sizes depending o...

Page 3: ...contacts of the coil it may lead to the malfunction of the device 2 When connecting the device for the first time or when changing the settings you should go to the settings menu To do so hold menu bu...

Page 4: ...lse to the coil Depending on the width of this impulse distance to the searched object also differs Also one can set up small and big coil in the optimum way But if the pulse induction width is big th...

Page 5: ...lfunction Filter When device is working with maximum sensitivity false actuations may occur In order to decrease number of false actuations please select one of four filters 0 Filter is off maximum se...

Page 6: ...e desirable backlight brightness of the display for work in badly lit places or in the night time To turn on off the backlight push backlight button on the main screen Display contrast Select the desi...

Page 7: ...ndition 5 Response scale to the metal 6 Button B1 Turn on off display backlight 7 Button B2 menu 8 Button B3 reset RESET Raise the coil off the ground and put it off away from the metal objects push b...

Page 8: ...increase on the response scale you will see divisions the number of which is proportionate to the size of metal object and distance to it To set up the required sound volume push button once B2 while...