iDevices IDEV0005 Installation Manual Download Page 10

18

19

Wiring Configurations

The following section provides the various  

wiring configurations compatible with the 

iDevices

®

 Thermostat. Find the configuration that 

matches closely to your old thermostat and note 

which system type you have for later reference.

Check your old thermostat to see if it has one or 

two Red/R wires. If you have two, connect one 

to RC, one to RH, and remove the jumper. If you 

have one R wire, connect it to RH and leave the 

jumper in place.

A.  Heat Only (One Stage)

 

Note: G wire is not required for hot-water baseboard or 

 

steam radiator systems. If G wire is not connected for a warm 

 

air heating system, Fan On mode will not be available.

Thermostat Settings

Stage:

 Non-HP  |  

Type:

 HE for electric, HG for gas/oil 

systems  |  Fan wire G optional for HG type

Note: G wire is not required for hot water baseboard or steam radiator systems. If G wire is 

not connected for a warm air heating system, Fan On mode will not be available.  

HUM

NC

W2/E

W1/O/B

RH

RC

Y2

Y1

G

L

C

If your system has two R wires, either Rc and Rh, or R and Rc

If your system has two R wires, 

either RC and RH, or R and RC:

Remove Jumper 

between RC and RH

If your system has one R wire:

Keep Jumper 

between RC and RH

NC

W2/E

W1/O/B

RH

RC

Y2

Y1

G

NC

W2/E

W1/O/B

RH

RC

Y2

Y1

G

Summary of Contents for IDEV0005

Page 1: ...1 Welcome To INSTALLATION GUIDE...

Page 2: ...EST Email Support iDevicesinc com Visit iDevicesinc com Support Please visit iDevicesinc com Compatiblity to see if your HVAC system is compatible Contents Introduction 3 In The Box 4 Display 5 Before...

Page 3: ...State 5 Button Lock 6 Connection Status 7 Fan Mode 1 2 3 4 7 6 5 In The Box iDevices Thermostat Mounting Hardware Requires Home Wi Fi Network Free iDevices Connected App 24VAC Common Wire Compatible...

Page 4: ...area with good airflow Avoid areas behind doors near corners heating or cooling vents heat generating devices or direct sunlight This Transmitter must be installed to provide a separation distance of...

Page 5: ...ed as a standalone heating system or as AUX Emergency heat with a heat pump system O B This option selects the type of reversing valve for heat pump systems An O reversing valve is energized when cool...

Page 6: ...system Using your old thermostat turn on the heating cooling functions if applicable to verify everything is functioning normally 3 If you have a heat pump system check the settings on your old thermo...

Page 7: ...he wires don t fall back into the wall by gently wrapping them around a pen Remove the mounting plate from the wall 12 Line up the iDevices Thermostat mounting plate on the wall in the desired locatio...

Page 8: ...ore timing out You can manually enter this mode from the Settings Setup Connect menu Connecting To The App And Wi Fi Network 1 Download and launch the free iDevices Connected app on your mobile device...

Page 9: ...EMERGENCY HEAT mode Adjust the temperature set point above the ambient temperature in the room and verify that the heat turns on 4 Note If you have a heat pump or air conditioner the iDevices Thermos...

Page 10: ...water baseboard or steam radiator systems If G wire is not connected for a warm air heating system Fan On mode will not be available Thermostat Settings Stage Non HP Type HE for electric HG for gas o...

Page 11: ...if G wire is not connected Fan On mode will not be available HUM NC W2 E W1 O B RH RC Y2 Y1 G L C Thermostat Settings Stage Non HP Type HG Note G wire is not required for hot water baseboard or steam...

Page 12: ...an On mode will not be available HUM NC W2 E W1 O B RH RC Y2 Y1 G L C Thermostat Settings Stage Non HP Type HE for electric HG for gas oil systems Note G wire is not required However if G wire is not...

Page 13: ...ode will not be available HUM NC W2 E W1 O B RH RC Y2 Y1 G L C Thermostat Settings Stage Non HP Type HE for electric HG for gas oil systems Thermostat Settings Stage Non HP Type HE for electric HG for...

Page 14: ...be available HUM NC W2 E W1 O B RH RC Y2 Y1 G L C Thermostat Settings Stage HP Type HG O B Type According to previous thermostat setting Note G wire is not required If G wire is not connected Fan On...

Page 15: ...NC W2 E W1 O B RH RC Y2 Y1 G L C Thermostat Settings Stage HP Type HG O B Type According to previous thermostat setting Note G wire is not required If G wire is not connected Fan On mode will not be a...

Page 16: ...p Call or email the iDevices Customer Experience Team with questions Call 888 313 7019 Monday Friday 8am 8pm EST Email Support iDevicesinc com Visit iDevicesinc com Support Note G wire is not required...

Page 17: ......

Page 18: ......

Page 19: ......

Reviews: