Product specifications, parameters, functions of the device can change without notice!
36
IDENTIVISION Megapixel camera installation guide
4.15.5
Camera parameters
40. picture
Camera parameters
[Expose]
choose automatic
(
0.1 milisecond-80 millisecond
)
, or
manual
(
1/25
,
1/50
,
1/120
,
1/250
,
1/500
,
1/1000
,
1/2000
,
1/4000
,
1/10000
),
default is automatic
[Day/night mode]
choose auto/color/ black and white, default is auto
;
[Backlight compensation]
choose on or off
;
[Auto iris]
choose on or off
;
[Profile]
choose indoor or outdoor or auto, default is auto
[AE reference]
choose integers data between 0—100, default is 50
;
[AGC]
choose on or off, limitation is between 0—100
;
[Slow shutter] choose none, low, medium, high, default is none.
[IR_CUT]
choose automatically switch or IR synchronous switch, default is automatically switch
[Mirror image]
tick
,
means enable the convert of left and right of monitoring page
[Over turn]
tick
,
means enable the convert of up and down of monitoring page.