A
11/
05
/
19
WIRING REFERENCE
EM-40-1
a
Relay Output
Nc
Normally Closed
C
Common
No
Normally Open
Relay Contact:
DC:
30 Vdc @ 1Adc
AC:
60 Vac @ 0.5Aac
Digital Contact Inputs
R1-2
Ground
In1-2
Non-Supervised or
Supervised Input 1-2
Optional DC Power In
0v
DC Power Ground
+12
DC Power Input
TB1 Requirements:
10 – 16 Vdc
350 mA
(300 mA external & 50
mA internal)
Wiegand Reader Input
+12
Power Output
0v
Ground
D1
Data 1 Input
D0
Data 0 Input
Ld
LED Output
Bz
Buzzer Output
Power Output using PoE:
12.0 – 12.5 Vdc
300 mA Max. Current
Power Output using DC:
8.5 – 16 Vdc
300 mA Max. Current
Reset Button
Press and hold this button for
10 seconds to reset the
configuration back to default.
50-40-1
NOTE:
As long as the total current of
the reader plus a door strike
DOES
NOT EXCEED 300mA
, you may
power the door strike using the
power out and ground from the
Reader Input terminal block.
1
1
2
3
4
5
2
3
4
5
SH
IE
LD