background image

A

11/

05

/

19

WIRING REFERENCE 

EM-40-1

a

 

Relay Output 

Nc 

Normally Closed 

Common 

No 

Normally Open 

Relay Contact: 

DC: 

30 Vdc @ 1Adc

AC: 

60 Vac @ 0.5Aac

Digital Contact Inputs 

R1-2 

Ground 

In1-2 

Non-Supervised or 
Supervised Input 1-2 

Optional DC Power In 

0v 

DC Power Ground 

+12

DC Power Input 

TB1 Requirements: 

10 – 16 Vdc

350 mA 

(300 mA external & 50

mA internal)

Wiegand Reader Input 

+12

Power Output 

0v 

Ground 

D1 

Data 1 Input 

D0 

Data 0 Input 

Ld 

LED Output 

Bz 

Buzzer Output 

Power Output using PoE: 

12.0 – 12.5 Vdc

300 mA Max. Current

Power Output using DC:

8.5 – 16 Vdc

300 mA Max. Current

Reset Button 

Press and hold this button for 

10 seconds to reset the 

configuration back to default.

 

50-40-1

NOTE: 

As long as the total current of 

the  reader  plus  a  door  strike 

DOES 

NOT  EXCEED  300mA

,  you  may 

power  the  door  strike  using  the 
power  out  and  ground  from  the 
Reader Input terminal block.

 

 

 

 

 

 

 

 

 

 

 

SH

IE

LD

 

Reviews: