background image

 
 
Installation and Operation Manual 

Page 6 of 11 

2

 

Safety Precautions 

Important Safety Note 
The devices described in this manual is for exclusive operation by trained employees. Only qualified personnel 
that know the potential dangers involved should perform the installation, settings, maintenance and repair of 
the units used. 

Operational Safety 
The correct and safe use of these systems assumes that operating and service personnel follow the safety 
measures described in the manual alongside the generally acceptable safety procedures. 
If there is a possibility that safe operation cannot be guaranteed the system must be switched off and secured 
against accidental use. Then the service unit responsible must be informed. 

Do not open the housing 
There is no need to open the housing. There are no user serviceable parts inside. Set-up and configuration 
during initial operation is done wireless with the built-in air interface. 

Handling Safety 
On account of high operating temperature of 80 °C (+176 °F) care must be taken, if the tags are heated. To 
avoid burn wait a while until the tags have cooled down or use gloves. At temperatures below 0 °C (+32 °F) 
tags can be iced. In this case, wait a while until tags are warmed up or use gloves.  

Battery Inside 
All tags contain a battery. That is the reason for the following instructions: 
 

Warning 

Fire, explosion and burn hazard 

Risk of explosion if battery is replaced by an incorrect type 

Do not recharge, short circuit, crush, disassemble, heat above 100 °C (212 °F) 

Do not incinerate, or expose contents to water 

 

Electrostatic Discharge 

This product contains components that are sensitive to electrostatic discharges. Please observe 
the special instructions for their protection. Incorrect handling can damage the unit and cause the 
invalidation of the warranty. 
 

Safety Documents 
This ILR system was designed, tested and supplied in perfect condition according to document test report 
EN60950. 

Condensation/Change of Temperature 
Moving the systems from a cold to a warm environment could lead to dangerous situations due to 
condensation. Therefore it must be ensured that the system can adjust itself to the warmer temperature. 

Spare Parts 
We recommend that only original products, spare and replacement parts authorized by IDENTEC SOLUTIONS 
be used for installation, service and repair. Otherwise IDENTEC SOLUTIONS does not accept any responsibility 
for materials used, work carried out or possible consequences. 

Summary of Contents for ILR 350 Series

Page 1: ...ILR 350 Series Installation and Operation Manual for Tag Models i Q350 i Q350T i Q350L i Q350TL...

Page 2: ...tation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such dam...

Page 3: ...ipment European Notification according R TTE Directive This equipment complies to Art 6 4 of R TTE Directive 1999 5 EC It is tested for compliance with the following standards ETSI EN 300 220 ETSI EN...

Page 4: ...D PROCEDURE 5 1 3 SCOPE OF THIS DOCUMENT 5 1 4 RESPONSIBILITY 5 1 5 ASSOCIATED DOCUMENTS 5 1 6 SCOPE OF DELIVERY VISUAL INSPECTION 5 2 SAFETY PRECAUTIONS 6 3 TAG MOUNTING TECHNIQUES 7 3 1 RIVETS 7 3 2...

Page 5: ...s the user s manual of this tag models i Q350 i Q350T i Q350L i Q350TL This document is intended only for mechanical installation rsp everyday use 1 4 Responsibility IDENTEC SOLUTIONS is not responsib...

Page 6: ...temperatures below 0 C 32 F tags can be iced In this case wait a while until tags are warmed up or use gloves Battery Inside All tags contain a battery That is the reason for the following instructio...

Page 7: ...a chance this might occur it is better to use a blind rivet with a large head Refer to UN9924 or insert a 3 16 washer This has the effect of distributing the pressure over a larger surface area durin...

Page 8: ...of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Depending on the type and strength category of the 10 screw used the maximum tightening torque must be b...

Page 9: ...soon as possible A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors securely fastened Are all screws still tight Is there suddenly a malfunct...

Page 10: ...e approved Operation mode Receives marker ID number and transmits marker information several times Electrical Power source Lithium battery not replaceable Battery monitoring Yes Temperature Logging Nu...

Page 11: ...i Q350TL Tag Manual Page 11 of 11 Dimensional Drawing All dimensions in mm External cable to temperature sensor models i Q350T i Q350TL not shown...