Technical Data
Operating Data
Operating frequency ILR-RFID
868 MHz (EU) or 920 MHz (NA), further frequencies on request
Transmission power
0.75mW (EU / NA)
Compatibility
depending on Broadcast Telegram Mode:
- ILR B2 (ASK) compatible with i-PORT MB, i-CARD CFB
- ILR 350 (FSK) compatible with i-PORT M 350, i-CARD CF 350
Standards/Certification
FCC Part 15 (US), ETSI EN 300 220 (EU)
Communication Data Long-Range RFID (ILR, Response Technology)
Multiple tag handling
Up to 2,000 tags in the read zone
Read/write range response mode
Up to 10 m (30 feet), free air*
Data rate response
19.2 to 115.2 kbits/s
Communication Data Long-Range RFID (ILR, Beacon Technology)
Read range broadcast
Up to 150 m (500 feet) free air*
Operation mode
Transmits marker information in at regular intervals
Repetition rate (ping rate)
0,5 – 300 seconds, adjustable in steps of 0,5 seconds
Data rate broadcast
115.2 kbits/s
* The communication range depends on the antenna type, the antenna cable runs and the
environmental conditions.
Communication Data Inductive Loop (Marker)
Read range
Up to several meters
Operating frequency
125 kHz (world-wide approved)
Operation mode
Receives marker ID number and transmits marker information several
times
Electrical Data
Power supply
Lithium battery
Configuration
Ping rate
Configurable from 0.5 to 300 seconds
in steps of 0.5 seconds
Number of Bursts
Configurable from 0 to 15
Environmental Conditions
Operating temperature
–30 to +70 °C (–22 to +158 °F)
Shock
50 G, 3 times acc. DIN IEC 68-2-27
several times onto concrete floor from 1 m height
Vibration
3 G, 20 sine wave cycles, 5 to 150 Hz,
DIN IEC 68-2-6
5 G, noise 5 to 1.000 Hz, 30 minutes
DIN IEC 68-2-64