background image

Microtag Manual

Page 10 of 11

5

 

Technical Data

Operating Data

Operating frequency ILR-RFID

868 MHz (EU) or 920 MHz (NA), further frequencies on request

Transmission power

0.75mW (EU / NA)

Compatibility

depending on Broadcast Telegram Mode:
-  ILR B2 (ASK) compatible with i-PORT MB, i-CARD CFB
-  ILR 350 (FSK) compatible with i-PORT M 350, i-CARD CF 350

Standards/Certification

FCC Part 15 (US), ETSI EN 300 220 (EU)

Communication Data Long-Range RFID (ILR, Response Technology)

Multiple tag handling

Up to 2,000 tags in the read zone

Read/write range response mode

Up to 10 m (30 feet), free air*

Data rate response

19.2 to 115.2 kbits/s

Communication Data Long-Range RFID (ILR, Beacon Technology)

Read range broadcast

Up to 150 m (500 feet) free air*

Operation mode

Transmits marker information in at regular intervals

Repetition rate (ping rate)

0,5 – 300 seconds, adjustable in steps of 0,5 seconds

Data rate broadcast

115.2 kbits/s

 

* The communication range depends on the antenna type, the antenna cable runs and the

environmental conditions.

Communication Data Inductive Loop (Marker)

Read range

Up to several meters

Operating frequency

125 kHz (world-wide approved)

Operation mode

Receives marker ID number and transmits marker information several
times

Electrical Data

Power supply

Lithium battery

Configuration

Ping rate

Configurable from 0.5 to 300 seconds
in steps of 0.5 seconds

Number of Bursts

Configurable from 0 to 15

Environmental Conditions

Operating temperature

–30 to +70 °C (–22 to +158 °F)

Shock

50 G, 3 times acc. DIN IEC 68-2-27
several times onto concrete floor from 1 m height

Vibration

3 G, 20 sine wave cycles, 5 to 150 Hz,
DIN IEC 68-2-6
5 G, noise 5 to 1.000 Hz, 30 minutes
DIN IEC 68-2-64

Summary of Contents for i-Q350L M

Page 1: ...i Q350L M Microtag Manual...

Page 2: ...ithout limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility...

Page 3: ...ean Notification according R TTE Directive This equipment complies to Art 6 4 of R TTE Directive 1999 5 EC It is tested for compliance with the following standards ETSI EN 300 220 ETSI EN 301 489 EN 6...

Page 4: ...SCOPE OF THIS DOCUMENT 5 1 4 RESPONSIBILITY 5 1 5 ASSOCIATED DOCUMENTS 5 1 6 SCOPE OF DELIVERY VISUAL INSPECTION 5 2 SAFETY PRECAUTIONS 6 3 INITIAL OPERATION 8 3 1 CONFIGURATION OF THE TAG 8 3 2 TAG H...

Page 5: ...ck of the tags and a system test can now be done 1 3 Scope of this Document This document is the user s manual of the model i Q350L M This document is intended only for mechanical installation rsp eve...

Page 6: ...of 70 C 158 F care must be taken if the tags are heated To avoid burn wait a while until the tags have cooled down or use gloves At temperatures below 0 C 32 F tags can be iced In this case wait a wh...

Page 7: ...only original products spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation service and repair Otherwise IDENTEC SOLUTIONS does not accept any responsibility for mater...

Page 8: ...o be configured The ping rate from 0 5 to 300 seconds in steps of 0 5 seconds The number of bursts from 0 to 15 factory default setting 5 Broadcast Telegram Mode ILR B2 ASK compatible with i PORT MB i...

Page 9: ...ble connections could lead to damage and malfunctions of the system and therefore should be repaired as soon as possible A Brief Checklist Are all housings intact Are all cables intact Are all connect...

Page 10: ...e Transmits marker information in at regular intervals Repetition rate ping rate 0 5 300 seconds adjustable in steps of 0 5 seconds Data rate broadcast 115 2 kbits s The communication range depends on...

Page 11: ...350L M Page 11 of 11 Mechanical Data Dimensions 56 mm 30 mm 14 mm Casing Plastics Mass 40 g Protection class IP 65 Certifications EMC CE EN 300 220 1 3 ETSI EN 301 489 1 3 FCC Part 15 US Industry Cana...