Maintenance 

3.1

 

General  

When installed correctly the ILR System will operate virtually maintenance free for many years. However, in 
the event maintenance is required only trained and authorized  personnel are permitted to perform the 
updates, changes and maintenance necessary.  
 

3.2

 

Regular Cleaning of The Surface 

Remove dust with a brush or compressed air. If there are fatty or oily substances use a soft cloth moistened 
with a mild rinsing agent. 

Warning 

Do not clean the tag in a dishwasher. Do not sandblast the tag. Do not use high pressure water jet or steam 
cleaner. Do not use cleaning products containing chemical additives. 
 

3.3

 

Precautionary Maintenance 

A regular check of the system is recommended. Unstable connections could lead to damage and malfunctions 
of the system and should therefore be repaired as soon as possible. 
 

A Brief Checklist 

 

Are all housings intact? 

 

Are all cables intact? 

 

Are all connectors intact? 

 

Are all connectors securely fastened? 

 

Are all screws still tight? 

 

Is there a malfunction at a specific unit? 

3.4

 

Returns  

Parts or main components returned for repair or exchange must be handled with great care. PC cards must be 
returned in the appropriate ESD-protecting packaging material. All returns should include an error description 
and a short application overview and be sent to the local distributor or to: 
 

IDENTEC SOLUTIONS AG 
Service Department 
Millenium Park 2 
6890 Lustenau 
AUSTRIA 

Summary of Contents for i-B350 S

Page 1: ...ILR 350 Series i B350L S Installation and Operation Manual preliminary...

Page 2: ...g from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages Trademarks IDENTEC...

Page 3: ...ucts are cautioned to only use accessories and peripherals approved in advance by IDENTEC SOLUTIONS The use of accessories and peripherals other than those approved by IDENTEC SOLUTIONS or any changes...

Page 4: ...PRECAUTIONS 3 TAG MOUNTING TECHNIQUES 5 3 1 DIMENSIONAL DRAWING 8 3 2 CABLE STRAPS 8 3 3 RIVETS 9 3 4 SCREWS 10 4 INITIAL OPERATION CONFIGURATION OF THE TAG 4 1 GENERAL 4 2 PING RATE 4 3 BURSTS WHEN P...

Page 5: ...the tags and a system test can now be done 1 3 Scope of this Document This document is the users manual of the models i B350 S and i B350L S This document is intended only for mechanical installation...

Page 6: ...8 F the tags are heated and must be handled with care To prevent burns wait until the tags have cooled down or use appropriate gloves At temperatures below 0 C 32 F tags can be frozen In this case wai...

Page 7: ...d that only original products spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation service and repair Otherwise IDENTEC SOLUTIONS does not accept any responsibility for...

Page 8: ...niques 1 1 Dimensional Drawing All dimensions in mm 1 2 Cable Straps The Tag can be mounted either with cable straps using the 2 slits at each end or using rivets or screws as described in the followi...

Page 9: ...this might occur it is better to use a blind rivet with a large head Refer to UN9924 or insert a 5 32 washer This has the effect of distributing the pressure over a larger surface area during riveting...

Page 10: ...need to be made of stainless steel or other non rusting material 4 A temperature of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Recommended maximum torq...

Page 11: ...gular Pings Marker technology Bursts triggered by the push button can be configured independent from regular Pings Tools Needed PC running on MS Windows with the ILR Tag Configuration for ILR 350 seri...

Page 12: ...rce to burst Possible settings are 40 100 200 300 400 500 600 and 700 ms Please read the details in the following subchapter Information on Burst Settings Marker Message Options Entering a marker fiel...

Page 13: ...l all bursts are sent With very few tags the factory setting of 40 ms is sufficient In case there is the possibility that dozens of tags are triggered to burst at once this value can be increased This...

Page 14: ...g products containing chemical additives 3 3 Precautionary Maintenance A regular check of the system is recommended Unstable connections could lead to damage and malfunctions of the system and should...

Page 15: ...itions Communication Data Inductive Loop Marker Read range Up to several meters Operating frequency 125 kHz world wide approved Operation mode Receives marker ID number and transmits marker informatio...

Reviews: