background image

IDEMIA DOCUMENT 

– REPRODUCTION AND DISCLOSURE PROHIBITED  

General precautions

Do not expose the terminal to extreme temperatures.

When the environment is very dry, avoid synthetic carpeting near the VisionPass terminal, to reduce the 

risk of unwanted electrostatic discharge.

Areas containing combustibles

Do not install the terminal in the vicinity of gas stations or any other installation containing flammable or 

combustible gases or materials. The terminal is not designed to be intrinsically safe.

The terminal should be installed in controlled lighting conditions

Avoid exposure of the biometric sensor to direct sunlight.

The terminal should be installed in controlled area in order to avoid water on the sensor 

Deployment Environment

10

Operating temperature 

-10° to +45 °C (14°to 113°F)

Operating humidity

10 % < RH < 80 % (non condensing)

Storage temperature

-25°to + 70 °C (-13°to 158°F)

Storage humidity

5% < RH < 95 %

St

ep 

one

 :

 ov

erv

iew

IDEMIA  - 2019_2000045730 

– V1

Summary of Contents for VisionPass

Page 1: ...All descriptions illustrations and specifications in this brochure should be considered approximate and may relate to optional equipment or feature Quick User Guide VisionPass...

Page 2: ...kaging checklist VisionPass box content 2 QTY ITEM 1 VisionPass terminal 1 Wall Mounting Plate 1 Documentation package Electronic documentation is provided in Adobe Acrobat format PDF Adobe Acrobat Re...

Page 3: ...NFPA 70 and the local authority having jurisdiction This product is intended to be installed with a power supply complying with IEC 60950 1 or IEC 62368 1 in accordance with the NEC Class 2 requireme...

Page 4: ...LOSURE PROHIBITED Table of Contents IDEMIA 2019_2000045730 V1 4 Color Step Content One Overview Two Wiring Three Communication Four SDAC Single Door Access Control Five Administration Six Software Sev...

Page 5: ...and Time Attendance Biometric authentication by face acquisition Simple and ergonomic man machine interface Contactless card reader MIFARE Classic MIFARE Plus DESFire HID Iclass HID PROX Universal con...

Page 6: ...sionPass is designed to operate in most environmental conditions Anyway to optimize VisionPass performance it is better to follow the rules below Avoid sunlight coming directly on the device for insta...

Page 7: ...r ID is listed in the Controller authorized user List Control of the latch is made through a dry contact An Alarm 3rd party product The terminal sends a message to the Access Controller to activate th...

Page 8: ...e terminal checks user s access rights using a biometric check If the result of the check is successful access granted a message is sent to the Central Access Controller for additional access rights c...

Page 9: ...n triggers are enabled Triggering events are selected by the remote application Biometric check if enabled The user s captured face is matched against all faces in the terminal database The user s cap...

Page 10: ...ther installation containing flammable or combustible gases or materials The terminal is not designed to be intrinsically safe The terminal should be installed in controlled lighting conditions Avoid...

Page 11: ...ew IDEMIA 2019_2000045730 V1 No User Guidance terminal acquisition volume is large enough to allow the user to be recognized easily as soon as he she looks at it This way is adapted to daily users Use...

Page 12: ...video stream is not recorded by the terminal it can be requested to disable the cameras when they are not necessary for privacy concerns VisionPass can be configured to enable the cameras on user req...

Page 13: ...4 5 6 ETH RX Green 7 8 Shell ETH GND Drain wire no color Wiegand IN Wiegand OUT 25 WIEGAND_LEDOUT1 Blue 28 WIEGAND_LEDOUT2 Blue Red 23 WIEGAND_IN1 White Red 24 WIEGAND_OUT0 Green 26 WIEGAND_OUT1 Whit...

Page 14: ...void the warranty Gauge AWG Section mm2 Maximum distance meters vs power source rating 12 V 10 3 6 A 12 V 5 3 5 A 24 V 10 2 A 24 V 10 3 A 16 1 31 6 m 12 m 68 m 121 m 18 0 82 4 m 8 m 43 m 76 m 20 0 52...

Page 15: ...uld be run in a daisy chain configuration i e converter position 1 position 2 position 3 etc Use CAT 5 UTP or better cable shielded recommended with a characteristic impedance of 120 ohms AWG 24 shoul...

Page 16: ...onverter terminal Use CAT 5 UTP or better cable shielded recommended with a impedance of 120 AWG 24 should be the minimum wire gauge used Choose one twisted pair of conductors to use for RS485_TX_Y TX...

Page 17: ...supported Use a category 6 shielding cable 120 Ohms or better It is strongly recommended to insert a repeater unit every 90 m Static mode is enabled by default on VisionPass terminals factory setting...

Page 18: ...WIEGAND_OUT1 White wire Pin 26 to ACP Data 1 Connect WIEGAND_GND Black Read wire Pin 27 to ACP reader common 0vDC For 18 AWG the maximum cable distance is 150m 500 ft for 20 AWG the maximum is 90m 30...

Page 19: ...k The Wiegand port also supports the Clock Data protocol The wiring is described below Example Format Information Type Standard 26 bit Alt Site Code and Fail Site Code Range 0 255 Template ID Number R...

Page 20: ...mple with Push Button Step four SDAC Power supply from electrical source shall be switched off before starting the installation IDEMIA 2019_2000045730 V1 13 RLY_NC Orange White 14 RLY_NO Yellow White...

Page 21: ...e used The internal relay is designed for 100 000 cycles If more cycles are needed an external relay driven by GPO must be used Step four SDAC IDEMIA 2019_2000045730 V1 13 RLY_NC Orange White 14 RLY_N...

Page 22: ...einitialize terminal main settings Local Administration First Boot Assistant 22 Main settings managed by FBA Date Time Time Zone Settings Trigger Event select event s to be processed as an access requ...

Page 23: ...to access to administrator menu default security code is 12345 For security reasons it is highly recommended to change the devices default password to a custom password Step five Administration Freque...

Page 24: ...plication 24 Terminal administration with MorphoBioToolBox MBTB application Step five Administration The VisionPass terminal can be configured using a dedicated Windows application MorphoBioToolBox Pl...

Page 25: ...ION AND DISCLOSURE PROHIBITED Software for Terminal Remote Administration and Enrollment IDEMIA 2019_2000045730 V1 25 Step six Software VisionPass Terminals are compatible with MorphoManager applicati...

Page 26: ...the local database with the option of creating a user RF card with the user s reference data Enrolment gathering user s data listed User s first name and last name User s face for biometric check User...

Page 27: ...SCLOSURE PROHIBITED Local Enrollment Process 2 2 IDEMIA 2019_2000045730 V1 27 Step seven capture basics Please stand still in front of the product with your face clearly visible Remove all non always...

Page 28: ...l settings NB Time to read all datas from the card would be more or less long depending on the quantities of datas to extract and type of card Contactless Card Position PIN input IDEMIA 2019_200004573...

Page 29: ...nformation is provided by the user through a specific screen displayed during identification or authentication process The new screen contains 4 dedicated function keys Entry Exit Beginning of a task...

Page 30: ...e and at least after significant changes in the database add remove or modification of user s records on a external support such a mass storage key Date Time synchronization The VisionPass terminal cl...

Page 31: ...It also contains the full description of all the configuration parameters for the terminal MWC VisionPass Parameters Guide Ref 2018_2000035285 This document contains the full description of all the t...

Page 32: ...log in and password please contact your sales representative Copyright 2020 IDEMIA All rights reserved www idemia com Reproduction in whole or in part in any form or medium without the express writte...

Reviews: