Kobra - Tongue Switches with Guard Locking - Type KL3-SS-P2L
IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070 Fax.: +44 (0)1942 257076
IDEM (USA) 4416 Technology Drive, Fremont, CA 94538 Tel:510-445-0751 Fax:1866-431-7064 email:
Web:
www.idemsafety.com
Standards:
EN1088, IEC 60947-5-1, UL508
Solenoid Voltage
24V dc
Solenoid consumption – Turn on current
Running current
1.2 A.
0.3A.
Safety Contacts 11-12 21-22
Utilization Category
AC15 A300 3A.
Thermal Current (Ith)
5A
Rated Insulation Voltage
600VAC
Rated Impulse Withstand Volt
2500VAC
Signal Contacts 33-34 43-44
AC15 A300 3A.
Travel for Positive Opening
10mm
Man. Actuation Frequency
2 cycle/sec
Actuator entry minimum radius
175mm
Case Material
Stainless steel 316
Actuator Material
Stainless steel 316
Enclosure Protection
IP69K
Operating Temperature
-25°C to 40°C
Mechanical Life Expectancy
1 x 10
6
Cycle min.
Vibration
IEC 68-2-6, 10-55Hz+1Hz,
Excursion: 0.35mm, 1 octave/min
Conduit Entry
M20 or ½” NPT (by Part Number)
Fixing
4 x M5
11/12
Open
Solenoid energised
21/22
Open
Solenoid energised
33/34
Closed
Locked
43/44
Open Tongue Inserted
Internal Terminal Connections:
Doc: 102549
May 2015
Information with regard to UL 508:
Type 1 Enclosures.
Use 16-12AWG copper conductors only.
Intended for same polarity use and
one polymeric conduit connection.
Electrical Rating: A300. 48W5.
Max. Switching Current / Volt / Amp:
120V. 6A. (720VA break) PF 0.38
240V. 3A. (720VA break) PF 0.38
Actuator insertion:
6.0 5 0mm
Internal Terminal Connections:
A1 0V dc
A2 24V.dc
11-12 Safety Circuit 1 –
(must always be used)
21-22
Safety Circuit 2
33-34 Signal Circuit Guard - (Closed when Guard is closed)
43-44 Signal Circuit Guard - (Closed when Guard is open)
LED Function:
Green Solenoid Energised