HS5E Miniature Interlock Switch with Solenoid

HS5B Miniature Interlock Switches

Ideal for applications in small spaces.

Available with a robust and durable metal head.
Choice of three conduit port sizes: G1/2, PG13.5, 
and M20

Compact body. 35 × 40 × 146 mm

 

Rear unlocking button type for emergency escape available.

 

Also available is a rear unlocking button kit.
A variety of circuit types—dual safety circuit and four-circuit independent 

 

output type available.
Spring lock and solenoid lock are available.

 

The head orientation can be rotated, allowing for 8 different actuator entries.

 

A metal entry slot ensures high durability of head.

 

The actuator retention force is 1000N minimum (GS-ET-19).

 

Rear Unlocking Button

Actuators are interchangeable with the HS5E interlock switches.

 

Actuators with rubber bushings are ideal for rattling doors.

 

The head orientation can be changed, allowing for 8 different actuator entries.

 

Compact body (30 × 30 × 90mm)

 

IDEC CORPORATION (USA)

1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550 / (800) 262-IDEC (4332) 
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: [email protected]

IDEC CANADA LIMITED

3155 Pepper Mill Court, Unit 4, Mississauga, 
Ontario, L5L 4X7, Canada
Tel: +1-905-890-8561, Toll Free: (888) 317-4332 
Fax: +1-905-890-8562
E-mail: [email protected]

IDEC AUSTRALIA PTY. LTD.

2/3 Macro Court, Rowville, Victoria 3178, Australia
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332
Fax: +61-3-9763-3255
E-mail: [email protected]

IDEC ELECTRONICS LIMITED

Unit 2, Beechwood, Chineham Business Park, 
Basingstoke, Hampshire RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: [email protected]

7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: [email protected]

Specifications and other descriptions in this catalog are subject to change without notice.

Cat. No. EP1210-0 MARCH 2008 7.2T PRINTED IN JAPAN

IDEC ELEKTROTECHNIK GmbH

Wendenstrasse 331, 20537 Hamburg, Germany
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: [email protected]

IDEC (SHANGHAI) CORPORATION

Room 608-609, 6F,  Gangtai Plaza, No. 700, 
Yan'an East Road, Shanghai 200001, PRC
Tel: +86-21-5353-1000, Fax: +86-21-5353-1263
E-mail: [email protected]

IDEC (BEIJING) CORPORATION

Room 211B, Tower B, The Grand Pacific Building, 
8A Guanghua Road, Chaoyang District, 
Beijing 100026, PRC
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119

IDEC (SHENZHEN) CORPORATION

Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park, 
Fu Tian District, Shenzhen, Guang Dong 518040, PRC
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944

IDEC IZUMI (H.K.) CO., LTD.

Units 11-15, Level 27, Tower 1, 
Millennium City 1, 388 Kwun Tong Road, 
Kwun Tong, Kowloon, Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: [email protected]

IDEC TAIWAN CORPORATION

8F-1, No. 79, Hsin Tai Wu Road, Sec. 1, 
Hsi-Chih, Taipei County, Taiwan 
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: [email protected]

IDEC IZUMI ASIA PTE. LTD.

No. 31, Tannery Lane #05-01,
HB Centre 2, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: [email protected]

www.idec.com

(08/03/12)

Summary of Contents for HS5B

Page 1: ...HS5B HS5E Door Handle Actuator Sliding Actuator 08 03 12...

Page 2: ...in an emergency situ ation and you need to escape from a hazardous area immediately If getting out requires multiple actions it is likely you will be trapped within the hazard ous area A system should...

Page 3: ...kplace in order to ensure safety Residual risk such as failure to install padlocks must be taken into con sideration Interlock switch with without solenoid locking can be selected LED shows solenoid s...

Page 4: ...Without Lock Large Small Door Size 20 X 30 mm X 3 mm 30 X 40 mm X 70 mm With Lock Without Lock Door Handle Actuator Configuration Selection Chart HS5E 44L G Rear Unlocking Button Type HS5B Z Metal Hea...

Page 5: ...r Left hand Door HS9Z DH5LH HS9Z DH5RH HS5B Z Metal Head Type HS5E All types HS5B Z Metal Head Type HS9Z DH5LH HS9Z DH5LH HS9Z DH5RH Sliding Actuator HS9Z SH5 HS5B Installation Kit HS9Z DH5B Rear Unlo...

Page 6: ...Interlock switch is not supplied with the actuator and must be ordered separately For the specifications of interlock switches see Cat No EP1199 0 Types Description Ordering Type No Remarks Handle Uni...

Page 7: ...Locked 81 Unlocked 84 Mounting Panel Thickness 20 to 40 3 Handle Link Shaft 8 free cutting steel LOCK UNLCOK 4 SUS SUS 10 4 Front Handle diecast aluminum black Rear Handle diecast aluminum yellow Rear...

Page 8: ...5 2 1 LOCK UNLOCK 4 3 PADLOCK Locked 81 Unlocked 84 Mounting Panel Thickness 70 mm or less Polyacetal black Handle Link Shaft 8 free cutting steel SUS SUS Rear Handle diecast aluminum yellow Rear Hand...

Page 9: ...unting panel of 3 mm or less in thick ness use the rear unlocking button When using the HS5B Z mounting panel thickness X 70mm When using the HS5E 44L G on the mounting panel of 20 to 40 mm in thickne...

Page 10: ...ckness of mounting panel 20 to 40 Pin SUS Screws iron Connecting Rod SUS Hinge Plate SUS HS5E 44L G Interlock Switch sold separetely Mounting Bracket 3 67 12 2 4 R 5 22 5 30 2 4 4 A6063 Anonized Dimen...

Page 11: ...locked sta tus otherwise the actuator will hit the door resulting in defor mation or damage When turning the handle make sure that your hands or fin gers are not caught by the door Cable Padlock Knob...

Page 12: ...t they do not become loose Shaft Positioning Pin Rear Handle Base Screw E Screw E Rear Handle Plate Rear Handle Shaft Install the rear handle yellow on the rear 6 handle shaft Mounting holes required...

Page 13: ...is closed and the main circuit remains open Safety Precautions Install the rear unlocking button in the place where only the operator inside the hazardous area can use it Do not install the button in...

Page 14: ...90N minimum 14 Sliding Actuator Dimensions 14 56 37 5 19 5 34 48 5 40 18 75 30 7 15 16 3 8 R2 6 13 26 5 51 32 5 34 6 M5 Screws 2 5 30 5 2 5 6 35 2 5 2 Actuator SUS Thickness 2 5 Cover SUS HS5B HS5E Sl...

Page 15: ...r is not trapped inside and the machine is not operated while the operator is in the hazardous zone Do not install the sliding actuator as shown below otherwise the actuator may be removed from the in...

Page 16: ...9763 3255 E mail sales au idec com IDEC ELECTRONICS LIMITED Unit 2 Beechwood Chineham Business Park Basingstoke Hampshire RG24 8WA UK Tel 44 1256 321000 Fax 44 1256 327755 E mail sales uk idec com 7...

Reviews: