IDEC HS1C Series Instruction Sheet Download Page 3

B-1909-1(0)

INSTRUCTION SHEET - HS1C Series 

Solenoid Type Safety Switch

( 3  / 5 )

2016.08

5

Contact Operation

Operation Cycle

Type

HS1C-

44R-

Type

HS1C-

144R-

Type

HS1C-

244R-

Type

HS1C-

344R-

3-4

 

: Closed

1-2 :  Open
5-6 :  Off
3-4 :  Closed
1-2 :  Open
5-6 :  Off
3-4 :  Closed
1-2 :  Closed
5-6 :  Off
3-4 :  Closed
1-2 :  Closed
5-6 :  Off

3-4 :  Open
1-2 :  Closed
5-6 :  Off
3-4 :  Open
1-2 :  Closed
5-6 :  Off
3-4 :  Open
1-2 :  Open
5-6 :  Off
3-4 :  Open
1-2 :  Open
5-6 :  Off

3-4 :  Open
1-2 :  Closed
5-6 :  On
3-4 :  Open
1-2 :  Open
5-6 :  On
3-4 :  Open
1-2 :  Open
5-6 :  On
3-4 :  Open
1-2 :  Closed
5-6 :  On

Main Circuit
Auxiliary Circuit
Solenoid Power
Main Circuit
Auxiliary Circuit
Solenoid Power
Main Circuit
Auxiliary Circuit
Solenoid Power
Main Circuit
Auxiliary Circuit
Solenoid Power

Closed

Closed

Open

• The machine can

be operated.

 

Door is locked.

• The machine can 

not be operated.

• Door is unlocked.

• The machine can 

not be operated.

6

Wiring

Wire Length inside the Safety Switch

Recommended Wire Core Size

Screw Terminal No.1, 2, 5, 6, 7, 8 : 0.5 to 0.75 mm

2

Screw Terminal No 3, 4, E             : 1.0 to 1.25 mm

2

Safety Switch

Connector

L1

L2

Screw

Terminal

No.

Wire Stripping

Leng h : L2 (mm)

Wire Length :

L1(mm)

7±1

Through Conduit Hole

70±2

65±2

60±2

55±2

50±2

45±2

110±2

35±2

45±2

30±2

30±2

25±2

25±2

30±2

30±2

65±2

65±2

85±2

45±2

50±2

55±2

60±2

65±2

70±2

35±2

110±2

45±2

1

2

3

4

5

6

7

8

E

1

2

3

Applicable Crimping Terminal

Screw Terminal No. 1 to 6 : Direct Wiring Using a solid or standed wire
Note : When using a stranded wire, make sure that adjoining terminals are not 

short-circuited with protruding core wires. Also, do not solder the core wires to 

avoid protruding wires.

<Ferrules> : Recommended ferrules (Phoenix Contact)

Crimping Tool : CRIMPFOX UD6

Applicable Wire

0.5 to 0.75mm

2

0.75 to 1.0mm

2

1.0 to 1.5mm

2

Type No.

AI 0.75-8 GY

AI 1.0-8 RD

AI 1.5-8 BK

Screw Terminal No. 7,8:

Terminal Screw (M3.5)

Screw Terminal No. E:

Ground Terminal Screw (M4)

3.8mm max.

7.6max.

3.5mm max.

3.6mm min.

L1

Φ3.6mm min.

6.9max.

L1

Φ4.1mm min.

3.5mm min.

Note :  Make sure to use an insulation tube 

on the crimping terminal.

Insulation Tube

Wire

Crimping Terminal

Approx. 4mm

9mm max.

Conduit Thread

30mm max.

Applicable Connectors

Use a connector with a degree of protection IP67.
• When using flexible conduit and metal connector
  Applicable Flexible Conduit Example
    : Type VF-03 (made by Nihon Flex)

  Applicable Metal Connector Example (G1/2) 

    : Type RLC-103 (made by Nihon Flex)
• When using plastic connector, metal connector and multi-core cable
 (G1/2)
    Applicable Plastic Connector Example : Type SCS-10

 (made by Seiwa Electric)

   

Applicable Metal Connector Example : Type ALS-16

□□

 (made by Nihon Frex)

  Note : Confirm the outside diameter of the multi-core cable, the connector type 

depends on the outside diameter of multi-core cable.

1

2

1

2

1

4

3

3

4

4

3

(

-

)

(

+

)

5

6

HS1C-R44R-

HS1C-R144R-

HS1C-R244R-

Main Circuit :

Monitor Circuit :

Monitor Circuit :

Main Circuit :

Main Circuit :

Main Circuit :

1

2

(

+

)

7

(

-

)

8

1

2

4

3

HS1C-R344R-

Main Circuit :

Monitor Circuit :

CAUTION

*7  The Actuator is inserted , and HS1C is locked.

Contact Configuration

Contact Configuration

 

*7

Type

Door monitor Lock monitor

Indicator