HR1S-ATE  Safety Relay Modules

HR1S-ATE Wiring Diagram

Safety Category 4 (3) Circuit

 

 

(using an emergency stop switch) 

(Note)

Safety

 

 Category 3 Circuit (using multiple emergency stop switches) 

Emergency stop switch - Input 2 channels 

 

When not detecting short-circuit 

(B1-S12 short-circuit not detected)

Emergency stop switch - Input 1 channel  

 

When not detecting short-circuit (All failures such as short-

circuit of emergency stop switch wiring not detected)

When monitoring the start switch 

 

(Y3-Y5 short-circuited)

When not monitoring the start switch 

 

(Y3-Y4 short-circuited) 

(automatic start when S33-Y2 is short-circuited)

S2

S1

S11

S21

A1

13

57 67

A2

S33

Y1

Y2 Y3 Y4 Y5

14 24

68

58

S22

B1

S12

23

F1

K2

K4 

K1

K1 

K3

L1 (+) 

N (–) 

K3

K4

K1

K2

Timer 1 

Time (s) 

Timer 2

T

ESC

K1

K2

K3

K4

HR1S-ATE 

LOGIC

77

78

Y88 Y89 Y90 Y91

Y+

(A1/A2)

(S12)

(S22)

(Stop 1)

+24V

(max. 4A)

 

Stop 

Category 0 

Stop 

Category 1 

K2 

HR1S-ATE 

HR1S-ATE 

HR1S-ATE 

HR1S-ATE 

 When monitoring the start switch, starts when switched off (default setting/recommended)

 

When monitoring the start switch, starts when switched on

 

Outputs must be fused (see the instruction manual for maximum fuse size)

 

To PLC, etc.

Note: When using off-delay output, safety category becomes 3.

S1 = Emergency stop switch with 2 NC contacts (recommended)
S2 = Start switch
ESC = External start conditions
Y1

 (

S33

)

 – Y2 = Feedback loop

S4

S11

S21

A1

13

57 67

A2

S33

Y1

Y2 Y3 Y4 Y5

14 24

68

58

S22

B1

S12

23

K2  K4 

K1

K1 

K3

N

(–) 

K3

K4

K1

K2

Timer 1 

Time (s) 

Timer 2 

T

ESC

K1
K2
K3
K4

HR1S-ATE 

LOGIC

77

78

Y88 Y89 Y90 Y91

Y+

(A

1/

A

2)

(S

12

)

(S

22

)

(S

to

p1

)

+24V

 

K2 

L1 (+)

F1

S3

21

22

11

12

S2

21

22

11

12

A2(+)

22

21

11

42

A1(–)

S1

2

1

1

2

S5

S6

52

41

51

12

Door Cover

K5
K6
K7
K8

K5

K6

K7

K8

External Output Circuit

S1

 

HS5E-D4001 Interlock Switch with Solenoid

S2, 3

 

XW1E-BV402 Emergency Stop Switch

S4

 

Start Switch (HW series momentary)

S5

 

Unlocking Enabling Switch

S6

 

Limit Switch, etc.

ESC

 

External Start Condition

K5 to 8

  

Contactor (forced guided type)

F1

 

Fuse 4A (gG)

Operations of Interlock Switch with Solenoid
(Stop)
Machine stops 

 Unlocking enabling switch ON 

→ 

Safety output OFF  

 Door cover released

(Start)
Door cover closed 

 Safety relay module start switch ON 

→ 

Safety output ON 

 Machine starts

Operations of Emergency stop switch
(Stop)
Press emergency stop switch 

 Safety output OFF 

→ 

Machine stops
(Reboot)
Emergency stop switch reset 

→ 

 

Safety relay module start switch ON 

  Safety output ON 

 Machine starts

Read instructions before configuring circuits.

HS5E-D4001

Interlock Switch with Solenoid

XW1E-BV402

Emergency stop switch

HS9Z-A51

Actuator

Safety category is achieved by an entire control 

system. Take the connected safety equipment 

and wiring into consideration.

(100705)