HR1S-ATE Safety Relay Modules
HR1S-ATE Wiring Diagram
Safety Category 4 (3) Circuit
•
(using an emergency stop switch)
(Note)
Safety
•
Category 3 Circuit (using multiple emergency stop switches)
Emergency stop switch - Input 2 channels
•
When not detecting short-circuit
(B1-S12 short-circuit not detected)
Emergency stop switch - Input 1 channel
•
When not detecting short-circuit (All failures such as short-
circuit of emergency stop switch wiring not detected)
When monitoring the start switch
•
(Y3-Y5 short-circuited)
When not monitoring the start switch
•
(Y3-Y4 short-circuited)
(automatic start when S33-Y2 is short-circuited)
S2
S1
S11
S21
A1
13
57 67
A2
S33
Y1
Y2 Y3 Y4 Y5
14 24
68
58
S22
B1
S12
23
F1
K2
K4
K1
K1
K3
L1 (+)
N (–)
K3
K4
K1
K2
Timer 1
Time (s)
Timer 2
T
ESC
K1
K2
K3
K4
HR1S-ATE
LOGIC
77
78
Y88 Y89 Y90 Y91
Y+
(A1/A2)
(S12)
(S22)
(Stop 1)
+24V
(max. 4A)
Stop
Category 0
Stop
Category 1
K2
HR1S-ATE
HR1S-ATE
HR1S-ATE
HR1S-ATE
When monitoring the start switch, starts when switched off (default setting/recommended)
When monitoring the start switch, starts when switched on
Outputs must be fused (see the instruction manual for maximum fuse size)
To PLC, etc.
Note: When using off-delay output, safety category becomes 3.
S1 = Emergency stop switch with 2 NC contacts (recommended)
S2 = Start switch
ESC = External start conditions
Y1
(
S33
)
– Y2 = Feedback loop
S4
S11
S21
A1
13
57 67
A2
S33
Y1
Y2 Y3 Y4 Y5
14 24
68
58
S22
B1
S12
23
K2 K4
K1
K1
K3
N
(–)
K3
K4
K1
K2
Timer 1
Time (s)
Timer 2
T
ESC
K1
K2
K3
K4
HR1S-ATE
LOGIC
77
78
Y88 Y89 Y90 Y91
Y+
(A
1/
A
2)
(S
12
)
(S
22
)
(S
to
p1
)
+24V
K2
L1 (+)
F1
S3
21
22
11
12
S2
21
22
11
12
A2(+)
22
21
11
42
A1(–)
S1
2
1
1
2
S5
S6
52
41
51
12
Door Cover
K5
K6
K7
K8
K5
K6
K7
K8
External Output Circuit
S1
:
HS5E-D4001 Interlock Switch with Solenoid
S2, 3
:
XW1E-BV402 Emergency Stop Switch
S4
:
Start Switch (HW series momentary)
S5
:
Unlocking Enabling Switch
S6
:
Limit Switch, etc.
ESC
:
External Start Condition
K5 to 8
:
Contactor (forced guided type)
F1
:
Fuse 4A (gG)
Operations of Interlock Switch with Solenoid
(Stop)
Machine stops
→
Unlocking enabling switch ON
→
Safety output OFF
→
Door cover released
(Start)
Door cover closed
→
Safety relay module start switch ON
→
Safety output ON
→
Machine starts
Operations of Emergency stop switch
(Stop)
Press emergency stop switch
→
Safety output OFF
→
Machine stops
(Reboot)
Emergency stop switch reset
→
Safety relay module start switch ON
→
Safety output ON
→
Machine starts
Read instructions before configuring circuits.
HS5E-D4001
Interlock Switch with Solenoid
XW1E-BV402
Emergency stop switch
HS9Z-A51
Actuator
Safety category is achieved by an entire control
system. Take the connected safety equipment
and wiring into consideration.
(100705)