background image

8.  Hold the thermostat 

approximately 2 

metres away from 

the boiler and 

“CONNECTING TO 

BOILER” will be 

displayed on your 

screen.

9.  After approximately 

60 seconds “Set 

System Time” will be 

displayed on your 

screen.  Use up and 

down arrows to set 

the time.  Once time is 

set press “DONE”

10. “Set System Date” will 

be displayed on your 

screen.  Use up and 

down arrows to set 

the date.  Once date is 

set press “DONE”.

QUICK START GUIDE

Logic Combi C / Logic Max Combi C / 

Vogue GEN2 Combi / Vogue Max Combi

In the unlikely event that commissioning is unsuccessful (e.g. central heating 

will not switch on or will not switch off), electrically isolate the boiler,               

remove 1 battery and repeat from step 6.

Blanking 

Plate

Transceiver

Slot

INSTALLATION

For User & Installation Guide please visit www.idealboilers.com

1.  Isolate electrical power to the 

boiler. 

2.  Remove the blanking plate by 

inserting flat blade screwdriver 

into slot situated centrally at 

bottom of blanking plate.

3.  Remove link wire plug & keep in 

a safe place.

4.  Connect the transceiver 

electrical plug.

5.  Locate and push the transceiver 

assembly into the boiler.

6.  Insert only 3 batteries into the 

Thermostat.

7.  Turn electrical power back on 

to the boiler and immediately 

insert the fourth battery into the 

Thermostat.

Summary of Contents for Touch Logic Combi C

Page 1: ...is unsuccessful e g central heating will not switch on or will not switch off electrically isolate the boiler remove 1 battery and repeat from step 6 Blanking Plate Transceiver Slot INSTALLATION For User Installation Guide please visit www idealboilers com 1 Isolate electrical power to the boiler 2 Remove the blanking plate by inserting flat blade screwdriver into slot situated centrally at bottom...

Page 2: ...t switch on check Target Room Temperature is at least 1 C greater than Actual Room Temperature If not press radiator symbol at bottom left of screen until On is highlighted then rotate outer ring clockwise If Central Heating will not switch off press radiator symbol until Off is highlighted 5 Check power to boiler is on boiler display should be on 6 If boiler transceiver left hand RF light is off ...

Page 3: ...e metallic objects e g American fridge freezer No large mirrors or windows No walls running along the RF path The Thermostat must not be within 1 metre of a WiFi booster router Rotate outer ring to change target temperature or to boost in an off period Press here to change Operating Mode Press MENU to access time programs and set time date Actual room temperature display ...

Page 4: ...where in the UK 01482 498660 Our normal working times excluding Bank Holidays are 8am 6pm Monday to Friday 8am 4pm Saturday 8am 12 noon Sunday 4 The guarantee does not apply a To any defect damage or breakdown caused by deliberate action accident misuse or third party interference including modification or failed batteries b To any defect damage or breakdown caused by the design installation and m...