Electricity Supply

This appliance is intended to be connected to the supply via a
double-pole switch, having a 3mm contact separation in both poles,
serving only the boiler and system controls. Alternatively, a 3-pin
UNSWITCHED socket may be used.  The fusing should be 3A.

IMPORTANT NOTES

THIS APPLIANCE MUST NOT BE OPERATED WITHOUT THE
CASING CORRECTLY FITTED.

If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.

Clearances of 180mm above, 100mm below, 5mm at the sides
and 450mm at the front of the boiler casing must be allowed
for servicing.

If it is known or suspected that a fault exists on the boiler then
it MUST 

NOT BE USED

 until the fault has been corrected by a

registered installer.

Legend
A

Control door

B

Control panel

C

On/off switch

D

Central heating on/off switch

E

Central heating pressure gauge

Introduction

The 

Systemiser SE

 is a wall mounted, room sealed, super efficient

condensing system boiler, featuring full sequence automatic spark
ignition and fan assisted combustion.

Due to the very high efficiency of the boiler, condensate is produced
from the flue gases and this is drained to a suitable disposal point
through the plastic waste pipe at the left lower rear of the boiler.  A
condensate 'plume' will also often be visible at the flue terminal.

Safety

Gas safety (Installation & Use) Regulations 1994,
amendments 1996 or rules in force.

In your own interest, and that of safety, it is the law that this boiler
must be installed by a registered installer, in accordance with all
national and local regulations.

It is essential that the instructions in this
booklet are strictly followed, for safe and
economical operation of the boiler.

BOILER CONTROLS

Summary of Contents for Systemiser SE

Page 1: ......

Page 2: ...before the boiler is fitted and it fits inside a cupboard Its compact size makes the Systemiser SE ideal for any kitchen It can be installed inside a cupboard without any ventilation Systemiser SE Th...

Page 3: ...C Appliance No 41 349 70 Gastec Certified P I No 0063 AS 3355 Destination Countries GB IE CAUTION To avoid the possibility of injury during the installation servicing or cleaning of this appliance car...

Page 4: ...nd A Control door B Control panel C On off switch D Central heating on off switch E Central heating pressure gauge Introduction The Systemiser SE is a wall mounted room sealed super efficient condensi...

Page 5: ...ds 10 o C If the flow temperature falls below 3 o C the boiler will fire until the temperature exceeds 10 o C Fault condition If the boiler will not light initially or if a fault develops during norma...

Page 6: ...251 Fax 01482 448 858 Registration No London 322 137 Registered Office National Avenue Kingston upon Hull HU5 4JN A subsidiary of Caradon p l c The code of practice for the installation commissioning...

Page 7: ...be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 01482...

Page 8: ...ion to the Ideal domestic boiler range The Ideal Householders Guide to assist the installer when presenting to his her customers Technical manuals required The Ideal C class combi boiler The Ideal Cla...

Reviews: