16
PEAK Hold Measurements
Function Range
Accuracy
Function Range
Accuracy
DC
400mV
unspecified
AC
400mV unspecified
Voltage
Voltage
4V +(1.5% +300)
4V
+(1.5% +300)
40V +(1.5% +60)
40V
+(1.5% +60)
400V
400V
1000V 750V
DC
40mA +(3% +60)
AC
40mA
+(3% +60)
Current Current
400mA
400mA
10A
+(1.5% +60)
10A
+(1.5% +60)
Note: With zero calibrated before measurement
4V ranges specify readings above 10% of full scale
Current ranges specify reading <90% of full scale
Noise generating fields may affect intervals
MIN/MAX
~Hz
PEAK
HOLD
Data Acquisition
2
Continuity Check
To Verify Continuity:
1. A continuity test ensures that all circuit connections are
intact.
2. Plug the Black test lead into the COM port and the Red
test lead into the
Ω
port.
3. Set the rotary switch to the
Ω
position.
4. Press the blue button until is shown in the display.
5. Connect the test leads to the circuit to be measured. The
buzzer will sound if the resistance of the circuit measured
is lower than 30
Ω
.
15
MIN/MAX
~Hz
PEAK
HOLD
Data Acquisition
2
Circuit Connection: