Safety

It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation of
the boiler.

Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer or in IE
a competent person, in accordance with the above regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a plug
and socket, serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.

Important Points

a.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

b.

The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.

c.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.

d.

Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or tampered
with.

In cases of repeated or continuous shutdown a CORGI registered
person or in IE a competent person should be called to investigate
and rectify the condition causing this and carry out an operational
test after each intervention on the device.  Only the manufacturer's
original parts should be used for replacement.

Minimum Clearances

A clearance of 533mm (21") MUST be available at the front of
the boiler for servicing.

The minimum clearances given in Table 1 MUST be complied
with, in order to maintain the safe running of the boiler.

To light the boiler.

Refer to Frame 2

If a programmer is fitted refer to separate instructions for the
programmer before continuing.

1.

Check that the electricity supply to the boiler is OFF.

2.

Open the control panel drop-down door and ensure that the
thermostat knob (G) is in the OFF position.

3.

Switch ON the electricity supply to the boiler and check that
all external controls, e.g. room thermostat etc., are ON.

4.

Set the boiler thermostat knob (G) to position 6. The fan will
start. After the fan has run for a few seconds the pilot
solenoid valve should open and the intermittent spark
commence, continuing until the pilot is established. The
main burner will then cross-light smoothly.

Winter conditions (i.e. central heating and domestic hot
water).

 The thermostat should  be positioned at setting 5 or 6.

Summer conditions (i.e. domestic hot water only).

 The

thermostat should be positioned at setting 2.

These settings are offered for general guidance only and other
settings may be found preferable, dependent upon the type of
system installed or as recommended by the installer.

Mexico Super FF440 ................. G.C. No.  41 392 26
Mexico Super FF450 ................. G.C. No.  41 392 27
Mexico Super FF460 ................. G.C. No.  41 392 28
Mexico Super FF470 ................. G.C. No.  41 392 29
Mexico Super FF480 ................. G.C. No.  41 392 30

MEXICO SUPER (Natural Gas Models Only)

Certified - P.I. No. 87 AU 83

Destination Countries:    GB, IE

1

BOILER CLEARANCES

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of

this appliance care should be taken when handling edges of sheet steel components

Table 1

Boiler

Flue

Dimension A

Model

Length

Rear Flue

Side/Top flue

mm (in.)

mm (in.)

mm (in.)

FF440, FF450

Up

10

35

FF460, FF470

to

(

3/8

)

(1 

3/8

)

FF480

600

FF440, FF450

600 to

FF460, FF470

3000

35

35

FF480

(23 

5/8

 to

(1 

3/8

)

(1 

3/8

)

118)

200939-1.p65

3/1/2004, 4:34 PM

46

Reviews: