IDEAL Mexico Super CF 3/60P User Manual Download Page 6

6

Mexico Super RS & CF Propane - Users

GAS LEAK

(usually detected by a distinctive smell)

DO NOT use electrical switches

DO NOT  look for a leak with a naked flame

IMMEDIATE ACTION:

CLOSE

 

all supply valves.

EXTINGUISH all sources of ignition.

Open all doors and windows.

If leakage cannot be stopped REMOVE CYLINDERS to
a safe place in the open air and advise the supplier.  If
this is not possible, evacuate the premises and call the
fire brigade.

Do not use the installation until it has been checked by a
CORGI registered installer.

leak detection solution around the connections - bubbles will
form if vapour is leaking.

NEVER USE A NAKED FLAME

f.

It is essential that the correct pressure regulator, with the correct
pressure setting and capacity for the installation, is used in
accordance with the manufacturer's instructions.

g.

In the case of a connection on a pressure regulator or gas
appliance which relies upon a sealing washer to maintain a
gastight joint, it is essential to check that the washer is present
and that it is sound and correctly positioned prior to making
the connection.  Where the connection relies on a metal-to-
metal seating or bullnose connection to obtain a gastight joint,
it is essential that the mating surfaces be clean and undamaged.

Under no circumstances should a damaged valve or connection
be used.

h.

Where connections are designed to be tightened with a
spanner, it is essential that a spanner of the correct size is
used and that the union is firmly tightened - hand tightness is
not sufficient.

When self sealing valves are incorporated in a gas cylinder,
connection should be made in accordance with the
manufacturer's instructions and tools should not be used.

i.

If the continuation of supply is interrupted when a cylinder is
changed, it is essential that all appliance taps are turned off
before the change is made.

j.

With bulk storage tanks always ensure that the site is kept clean
and clear of rubbish.  Such vessels are designed to be filled on
site by the gas distributors.

EMERGENCY ACTION

EMERGENCY ACTION

FIRE

IMMEDIATE ACTION:

IF SAFE TO DO SO

, SHUT OFF THE GAS SUPPLY

Do not attempt to extinguish gas flame by any other means.

Raise the alarm and call the fire brigade

 stating that a

liquefied petroleum gas cylinder is involved, and give its location.

DO NOT GO NEAR A CYLINDER if a cylinder is being heated
by fire.

ALERT EVERYONE in the immediate area of the fire and
evacuate the building.

ADVISE THE FIRE BRIGADE on their ARRIVAL of the
LOCATION of the cylinder.

If a cylinder is not involved in the fire and it is SAFE TO DO SO,
close all cylinder valves and remove the cylinders to a safe
place.

6

6

6

6

6

CARADON PLUMBING Ltd.

 pursues a policy of continuing

i m p r o v e m e n t   i n   t h e   d e s i g n   a n d   p e r f o r m a n c e   o f   i t s
p r o d u c t s .   T h e   r i g h t   i s   t h e r e f o r e   r e s e r v e d   t o   v a r y
specification without notice.

CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:1994
Quality System accepted by BSI

September 1999

151915 A02

CARADON PLUMBING Ltd

, P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN. Telephone:

01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Registered Office: National
Avenue, Kingston upon Hull, HU5 4JN. 

A subsidiary of Caradon p.l.c

Ideal Consumer Helpline: 01482 498660

The code of practice for the installation,

commissioning & servicing of central heating systems

Caradon Plumbing Limited is a member of the

Benchmark initiative and fully supports the aims of the

programme.  Benchmark has been introduced to

improve the standards of installation and

commissioning of central heating systems in the UK

and to encourage the regular servicing of all central

heating systems to ensure safety and efficiency.

Summary of Contents for Mexico Super CF 3/60P

Page 1: ......

Page 2: ...an easy to use programmer kit available on all models an overheat thermostat kit for all models and a pump kit that can be housed within the casing available for all models except the Super CF 3 140 C...

Page 3: ...ty to the appliance Materials giving off flammable vapours must not be stored in the same room as the appliance e Under NO circumstances should any of the sealed components on this appliance be used i...

Page 4: ...he boiler will light Set the boiler thermostat to the desired setting 9 Refit the lower front panel by locating the bottom edge behind the top of the grille assembly and pushing the panel backward to...

Page 5: ...be consulted DO NOT FIRE THE BOILER IF THE PRESSURE HAS REDUCED TO ZERO FROM THE ORIGINAL SETTING Escape of gas See Emergency Action Notice on the back page Do NOT search for gas leaks with a naked fl...

Page 6: ...terrupted when a cylinder is changed it is essential that all appliance taps are turned off before the change is made j With bulk storage tanks always ensure that the site is kept clean and clear of r...