IDEAL icos M3080 User Manual Download Page 3

Supplied By www.heating spares.co  Tel. 0161 620 6677

3

icos system - 

User's

Legend

Boiler ON/OFF switch

Mains on neon

Display

Reset button

LED

F

CH thermostat knob

Condensate drain

Pressure gauge

A

B

F

D

E

C

H

G

2093

To light the boiler. Refer to Frame 1

If a programmer is fitted  refer to separate instructions for the
programmer before continuing.

1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER

IS OFF.

2. Set the mains ON/OFF switch (A) to OFF and the thermostat

knob (F) to maximum.

3. Switch ON the electricity supply to the boiler and check that

all external controls, e.g. programmer, room thermostat, etc.,
are ON.

4. Set the mains ON/OFF switch to ON.

The mains on neon (B) will illuminate and the boiler will
commence the ignition sequence, supplying heat to the central
heating, if required.

Note. In normal operation the control unit display (C) will show
the codes:

Standby - no demand for heat.

CH being supplied.

During ignition, the LED (E) will flash.

During normal running the LED (E) will remain illuminated.

Note.
If the boiler fails to light after 3 attempts the fault code 

L  F 

will be

displayed.

Press the reset button (D) for 2 seconds then release. The boiler
will repeat the ignition sequence. If the boiler still fails to light
consult a CORGI registered installer or in IE a competent
person.

Note.
The pump will operate briefly as a self-check, once every 24
hours regardless of system demand.

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of

this appliance care should be taken when handling edges of sheet steel components.

1

BOILER controls

Control of water temperature

The boiler controls the central heating radiator temperature to a
maximum of 82

o

C, adjustable via the thermostat knob (F).

To shut down the boiler

1. For short periods

Set the mains ON/OFF switch (A) to OFF

2. For longer periods

Set the mains ON/OFF switch (A) to OFF, and switch the
electricity supply to OFF.

For longer periods the entire system should be drained.

To relight the boiler

Repeat the procedure detailed in 'To light the boiler'.

Approx. flow temperatures for the boiler thermostat settings are:

Knob Setting

Flow Temperature

°C

°F

Minimum

30

86

Maximum

82

180

Reviews: