mexico HE 

Users

Control of water temperature

The boiler controls the central heating radiator temperature to a 

maximum of 82

0

C, adjustable via the CH thermostat knob (B).

Approx. CH flow temperatures for the boiler thermostat settings 

are:

 

Knob setting 

Flow Temperature

  

F

 

Minimum

  30 86

 

Maximum

  82 180

To shut down the boiler

1.  For short periods

 

Set the mains on/off switch (A) to OFF.

2.  For longer periods

 

Set the mains on/off switch (A) to OFF.  Switch the electricity 

supply to OFF.    For longer periods the entire system should be 

drained, including the domestic hot water supply.

To relight the boiler

Repeat the procedure detailed in ‘To light the boiler’.

Frost protection

if no frost protection is provided and frost is likely during a short 

absence from home leave the heating controls (if fitted) at a 

reduced temperature setting.
For longer periods the entire system should be drained.
if the system includes a frost thermostat then, during cold 

weather, the boiler should be turned 

OFF

 at the time switch (if 

fitted) ONLy.  The mains supply should be left switched 

ON,

 with 

the boiler thermostat left in the normal running position.

Boiler Overheat Thermostat

This thermostat will shut down the boiler in the event of 

overheating.  Should this occur a fault code ‘

L-A

’ will be displayed.  

Press the reset button (C) and the boiler will relight.  if the fault 

recurs turn off the boiler and consult a Gas Safe Registered 

Engineer or in iE a Registered Gas installer.

Flame failure

Should this occur a fault code ‘

L-F

’ will be displayed.  Press the 

reset button and the boiler will relight.  if the fault recurs, turn off 

the boiler and consult a Gas Safe Registered Engineer or in iE a 

Registered Gas installer.

Condensate Drain

This appliance is fitted with a siphonic condensate trap system that 

reduces the risk of the appliance condensate from freezing.  However 

should the condensate pipe to this appliance freeze, please follow 

these instructions:
a.  if you do not feel competent to carry out the defrosting 

instructions below please call your local Gas Safe Registered 

installer for assistance.

b.  if you do feel competent to carry out the following instructions 

please do so with care when handling hot utensils.  Do not 

attempt to thaw pipework above ground level.

if this appliance develops a blockage in its condensate pipe, the 

condensate will build up to a point where it will make a gurgling 

noise  prior  to  locking  out  an  “L2”  fault  code.    if  the  appliance  is 

reset it will make a gurgling noise prior to it locking out on a failed 

ignition “L2” code.
To unblock a frozen condensate pipe;
1.  Follow the routing of the plastic pipe from its exit point on the 

appliance, through its route to its termination point.

  Locate the frozen blockage.  it is likely that the pipe is frozen 

at the most exposed point external to the building or where 

there is some obstruction to flow.  This could be at the open 

end of the pipe, at a bend or elbow, or where there is a dip in 

the pipe in which condensate can collect.  The location of the 

blockage should be identified as closely as possible before 

taking further action.

2.  Apply a hot water bottle, microwaveable heat pack or a warm 

damp cloth to the frozen blockage area.  Several applications 

may have to be made before it fully defrosts.  Warm water can 

also be poured onto the pipe from a watering can or similar.  

DO NOT use boiling water.

3.  Caution when using warm water as this may freeze and cause 

other localised hazards.

4.  Once the blockage is removed and the condensate can flow 

freely, reset the appliance (Refer to “To Light the boiler”)

5.  if the appliance fails to ignite, call your Gas Safe Registered 

engineer.

preventative solutions

During cold weather, set the boiler stat to maximum, (Must return to 

original setting once cold spell is over)
Place the heating on continuous and turn the room stat down to 15ºC 

overnight or when unoccupied. (Return to normal after cold spell).

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of 

this appliance care should be taken when handling edges of sheet steel components.

Legend

A

 

Boiler on/off switch

B

 

CH thermostat knob

C

 

Reset button

D

 

LED

E

 

Display

BOiLEr COnTrOLS

mhe7554

E

C

D

B

A

Reviews: