POINTS FOR THE BOILER USER

Note.

  

In line with our current warranty policy we would ask that you check through the following guide to identify any

problems external to the boiler prior to requesting a service engineers visit.  Should the problem be found to be other than
with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained
by the engineer.

TROUBLESHOOTING - TYPICAL NON PRODUCT FAULTS

Problem

Solution

Boiler is not working for
central heating or hot water.

Turn up the thermostat control knob (B).

Check overheat thermostat reset button (D) if optional kit fitted. The boiler should then relight –
If the fault recurs turn off the boiler and contact the installer.

Boiler goes through the
ignition sequence but will not
fire for central heating or hot
water.

Check gas supply (try at another gas appliance e.g. cooker / fire) – If no gas supply then not a
boiler fault – contact your gas supplier.

Boiler is operating
satisfactorily for domestic hot
water but will not operate for
central heating.

If an external programmer is fitted check that the central heating channel is at an ‘on’ period

Check that the room thermostat is set at the required temperature. Test the room thermostat
by turning this fully up – if this does not respond contact your installer.

Boiler is operating
satisfactorily for central
heating but will not operate
for domestic hot water.

If an external programmer is fitted check that the domestic hot water channel is at an ‘on’
period.

Check that the domestic hot water cylinder thermostat is set at the required temperature. Test
the cylinder thermostat by turning this fully up – if this does not respond contact your installer.

Boiler will not fire the pilot
light is lit but the igniter
continues to spark and the
main burner does not ignite.

This is a symptom of crossed polarity i.e. the live and neutral supply to the boiler are crossed
over. This is not a boiler fault contact your installer to correct the wiring.

If the boiler is fitted with a
sealed system kit.

Check pressure gauge on the boiler this should read a minimum of 1 bar If below 1 bar re-
pressurise the system via the filling loop. Once pressure reaches 1 bar turn off the tap on the
filling loop and press the overheat thermostat reset button (E) to reset the boiler. If unable to
do so or if the pressure continues to drop after refilling contact your installer.

Summary of Contents for Classic SE9 RS

Page 1: ...NGINEERED FOR PEACE OF MIND When replacing a part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers SE9 RS SE12 RS SE15 RS SE18 RS ...

Page 2: ...ation Use Regulations or rules in force In your own interest and that of safety it is the law that this boiler must be installed by a CORGI registered installer or in IE a competent person in accordance with the above regulations Electricity Supply This appliance must be efficiently earthed Supply 230 V 50 Hz The fusing should be 3A Connection must be made in a way that allows complete isolation o...

Page 3: ...card and have a registration number Both should be recorded in your Benchmark Log Book You can check your installer by calling CORGI direct on 01563 72300 THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introduced to improve the standard...

Page 4: ...a boiler fault contact your gas supplier Boiler is operating satisfactorily for domestic hot water but will not operate for central heating If an external programmer is fitted check that the central heating channel is at an on period Check that the room thermostat is set at the required temperature Test the room thermostat by turning this fully up if this does not respond contact your installer Bo...

Reviews: