4
Classic LXFF & FF -
User's
To light the boiler.
Refer to Frame 1
1.
CHECK THAT THE ELECTRICITY SUPPLY TO THE
BOILER IS OFF.
2. Deluxe Model (LX)
- Lift the glass fascia and support it with
the sliding catch.
Standard Model
- Open the controls access door by hinging
downwards.
3.
Ensure that the gas inlet cock (B) is OPEN.
4.
Press the overheat reset button (D), located as shown in
Frame 1.
5.
Ensure that the mains on/off switch (E) is in the OFF
position.
6.
Switch ON the electricity supply to the boiler. Check that all
external controls, e.g. room thermostat etc., are ON.
7.
Turn the boiler thermostat knob (C) to position 6 and the
mains on/off switch (E) to ON. After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.
8. Deluxe Model (LX)
- Lower the glass fascia after pushing in
the sliding catch.
Standard Model
- Close the controls access door.
NOTE TO THE INSTALLER:
LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER
In
winter conditions
, i.e. central heating and domestic hot
water, the thermostat should be set at position 5 or 6.
For
summer conditions
, i.e. domestic hot water only, the
thermostat should be set at position 3.
These settings, however, are offered for general guidance only
and other settings may be found preferable, dependent upon the
type of system installed or as recommended by the installer.
Approximate flow temperatures for the boiler thermostat settings
are:
Knob Setting
Flow Temperature
°C
°F
1
56
133
2
61
142
3
66
152
4
72
161
5
77
170
6
82
180
1 BOILER CONTROLS
LEGEND
A
Sightglass
B
Gas inlet cock (shown in the OPEN position)
C
Thermostat knob
D
Overheat thermostat reset button
E
Mains on/off switch
View
inside
boiler
controls
area
Deluxe Model (LX)
Standard Model