background image

GAS LEAK

(usually detected by a distinctive smell)

DO NOT use electrical switches

DO NOT  look for a leak with a naked flame

IMMEDIATE ACTION:

CLOSE

 all supply valves.

EXTINGUISH all sources of ignition.

Open all doors and windows.

If leakage cannot be stopped REMOVE CYLINDERS to a
safe place in the open air and advise the supplier.  If this
is not possible, evacuate the premises and call the fire
brigade.

Do not use the installation until it has been checked by a
CORGI registered installer or in IE a competent person.

EMERGENCY ACTION

EMERGENCY ACTION

FIRE

IMMEDIATE ACTION:

IF SAFE TO DO SO, SHUT OFF THE GAS SUPPLY

Do not attempt to extinguish gas flame by any other means.

Raise the alarm and call the fire brigade

 stating that a  liquefied

petroleum gas cylinder is involved, and give its location.

DO NOT GO NEAR A CYLINDER if a cylinder is being heated by
fire.

ALERT EVERYONE in the immediate area of the fire and
evacuate the building.

ADVISE THE FIRE BRIGADE on their ARRIVAL of the LOCATION
of the cylinder.

If a cylinder is not involved in the fire and it is SAFE TO DO SO,
close all cylinder valves and remove the cylinders to a safe
place.

e.

Ensure that the replacement cylinder connections are gastight.
Any leaking  vapour will have a distinctive odour.  Test by using
leak detection solution around the connections - bubbles will
form if vapour is leaking.

NEVER USE A NAKED FLAME

f.

It is essential that the correct pressure regulator, with the correct
pressure setting and capacity for the installation, is used in
accordance with the manufacturer's instructions.

g.

In the case of a connection on a pressure regulator or gas
appliance which relies upon a sealing washer to maintain a
gastight joint, it is essential to check that the washer is
present and that it is sound and correctly positioned prior to
making the connection.  Where the connection relies on a
metal-to-metal seating or bullnose connection to obtain a
gastight joint, it is essential that the mating surfaces be clean
and undamaged.

Under no circumstances should a damaged valve or
connection be used.

h.

Where connections are designed to be tightened with a spanner,
it is essential that a spanner of the correct size is used and that
the union is firmly tightened - hand tightness is not sufficient.

When self sealing valves are incorporated in a gas cylinder,
connection should be made in accordance with the
manufacturer's instructions and tools should not be used.

i.

If the continuation of supply is interrupted when a cylinder is
changed, it is essential that all appliance taps are turned off
before the change is made.

j.

With bulk storage tanks always ensure that the site is kept clean
and clear of rubbish.  Such vessels are designed to be filled on
site by the gas distributors.

Ideal Consumer Helpline Tel: 01482 498 660

www.idealboilers.com

The code of practice for the installation,

commissioning & servicing of central heating systems

Caradon Ideal Limited. is a member of the Benchmark initiative
and fully supports the aims of the programme. Benchmark has
been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to
encourage the regular servicing of all central heating systems to
ensure safety and efficiency.

March 2003

UIN 157366 A02

Caradon Ideal Limited

 pursues a policy of continuing improvement

in the design and performance of its products. The right is therefore
reserved to vary specification without notice.

Ideal Boilers

,  P.O. Box 103, National Ave, Kingston upon Hull,

HU5 4JN. Telephone:  01482 492 251 Fax: 01482 448 858.
Registration No. London 322 137.

Reviews: