4. CABLE STRIPPING DIMENSIONS FOR PRIMARY POWER CONTACTS
5. RECOMMENDED SOLDERING TECHNIQUES
(Use rosin flux solder only). Wrap cable strands, melt solder into well; heat and insert stripped cable. Continue
heating well until solder flows into wire being careful not to over flow onto contact surfaces. DO NOT SOLDER DIP
CONTACTS when contacts are soldered to unsupported lead. Underwriters’ Laboratories, Inc. requires use of cable
clamps, listed in table below.
6. CABLE / CONTACT & HOUSING ASSEMBLY
Observing polarity of markings, push each contact into rear of housing until notched side snaps
over spring, tug on cable to make sure contact is locked into place.
DISASSEMBLING CONNECTORS (see illustration)
Switch off power first. Remove contact by inserting extraction tool (cat. no. SBE160 / SBX175 - 969P1, SBE320 /
SBX350 - 970P1) as shown below (steps 1, 2, & 3).
CAUTION: Replace contacts individually on battery leads to reduce potential danger of shorting.
1. Insert extraction tool as shown between contact and housing to point A.
2. Press down to release contact from spring.
3. Pull cable to remove contact.
Connector
For Two Single
Ampere Rating Conductor Cables
SBE320 / SBX350
911G2
SBE160 / SBX175
945G2
Connector
Strip “X” To
Series
Inches mm
SBE320 / SBX350
1 3/8
35
SBE160 / SBX175
1 1/8
29
SBE
®
/ SBX
®
Assembly Instructions
X
Extraction Tool
2
3
Point A
Extraction Tool