background image

7. CABLE / CONTACT & HOUSING ASSEMBLY

Observing polarity of markings, push each contact into rear of housing until notched side snaps over spring, tug on cable to make sure 
contact is locked into place.

DISASSEMBLING CONNECTORS (see illustration)

Switch off power fi rst. Remove contact by inserting extraction tool (cat. no. SBE160 / SBX175 - 969P1, SBE320 / SBX350 - 970P1) as 
shown below (steps 1, 2, & 3).

CAUTION: Replace contacts individually on battery leads to reduce potential danger of shorting.

1. Insert extraction tool as shown between contact and housing to point A.

2. Press down to release contact from spring.

3.  Pull cable to remove contact.  

3.  Pull cable to remove contact.

Contains two each of : housings, contacts, retaining pins & cable ties.

1. Single conductors use #12 to #18 AWG wire only. Strip to 0.31 inch (7.9 mm) off end of insulation.

2. Twin conductor cable #12 to #18. Strip back outer jacket 5.50 inches (139 mm). (See illustration). Then strip conductor insulation as in  
(fi gure 1).

3a. To crimp: use the recommended tool. Crimping by other means may disturb contact position in housing and or produce high 
resistance joints.

3b. To Solder: Not recommended.

Extraction Tool

2

3

Point A

Extraction Tool

Catalog  

 

Wire  Retaining

Number  

Application  

Contact  

Size  

Pin Length

6344  

SBE80, SBE160, SBO60, SBX175  

1331  

#12/16  

0.85

6305G1  

SBE320, SBX350  

1331  

#12/16  

1.00

6310G1  

SBE320, SBX350  

1332  

#16/20  

1.00

Crimp Tool  

Catalog Number

Manual - cycle controlled  

1309G2

Pneumatic - cycle controlled  

1367G1

ASSEMBLY INSTRUCTIONS

NOTE: These assembly instructions apply only to the catalog numbers listed below 

(SBE

®

, SBX

®

, SBO

®

).  

[139]

5.5

[7.9]
0.31

Figure 1

Reviews: