Saf-D-Grid

®

Assembly Instructions for AC Saf-D-Grid

®

 Ultra Short Receptacle

Page 2

Figure 6

Figure 7

Figure 8

http://youtu.be/Xh64r_LwvWA

For demonstration of

 Soldering Method #1

, see the below referenced video on YouTube.

Soldering Method #2, 2300GX Series

Saf-D-Grid Receptacle with contacts sold separately

A 1/8” wide screwdriver tip and Ø.032” lead-free solder is recommended 

for use.  Solder of 99.2 Sn/0.3 Ag/0.5 Cu composition works well.

Prior to soldering, strip back the wire insulation 0.35” ± 0.01” (8.9 mm ± 

0.3 mm).  2016G1-LPBK contacts should be used with 18 AWG wires 

only. 2016G2-LPBK contacts should be used with 12 and 10 AWG wires.

The conductors should be looped through the hole in the contact prior to 

soldering (Figure 6).  Example solder joints are shown in (Figure 7).

Once the contacts have been soldered, they should be inserted into the 
receptacle housing (Figure 8).   The ground contact should be inserted 
into the top position,        perpendicular to the power contacts.  The line 
wire should be inserted in the position marked with a “L” on the bottom of 
the housing.  The neutral wire should be inserted in the position marked 
with a “N” on the bottom of the housing.  Once the contacts have been 
inserted, pull slightly to verify they are fully seated past the internal spring.

All Data Subject To Change Without Notice                                                                                                                                                                                  1S6648     REV 0

TRADEMARKS: “Saf-D-Grid, APP and Anderson Power Products are registered USA and foreign trademarks of Anderson Power Products”.  
PATENTS: This product is patented.  HEADQUARTERS: Anderson Power Products

®

, 13 Pratts Junction Road, Sterling,MA 01564 USA  T: 978-422-3600  F:978-422-0128 

 

www.andersonpower.com