Saf-D-Grid
®
Assembly Instructions for AC Saf-D-Grid
®
Ultra Short Receptacle
Page 2
Figure 6
Figure 7
Figure 8
http://youtu.be/Xh64r_LwvWA
For demonstration of
Soldering Method #1
, see the below referenced video on YouTube.
Soldering Method #2, 2300GX Series
Saf-D-Grid Receptacle with contacts sold separately
A 1/8” wide screwdriver tip and Ø.032” lead-free solder is recommended
for use. Solder of 99.2 Sn/0.3 Ag/0.5 Cu composition works well.
Prior to soldering, strip back the wire insulation 0.35” ± 0.01” (8.9 mm ±
0.3 mm). 2016G1-LPBK contacts should be used with 18 AWG wires
only. 2016G2-LPBK contacts should be used with 12 and 10 AWG wires.
The conductors should be looped through the hole in the contact prior to
soldering (Figure 6). Example solder joints are shown in (Figure 7).
Once the contacts have been soldered, they should be inserted into the
receptacle housing (Figure 8). The ground contact should be inserted
into the top position, perpendicular to the power contacts. The line
wire should be inserted in the position marked with a “L” on the bottom of
the housing. The neutral wire should be inserted in the position marked
with a “N” on the bottom of the housing. Once the contacts have been
inserted, pull slightly to verify they are fully seated past the internal spring.
All Data Subject To Change Without Notice 1S6648 REV 0
TRADEMARKS: “Saf-D-Grid, APP and Anderson Power Products are registered USA and foreign trademarks of Anderson Power Products”.
PATENTS: This product is patented. HEADQUARTERS: Anderson Power Products
®
, 13 Pratts Junction Road, Sterling,MA 01564 USA T: 978-422-3600 F:978-422-0128
www.andersonpower.com
Ground Contact