11

Ranges & Accuracies:

AC Converter:  

61-763, 61-765 models are true rms sensing.

Accuracy:  

Accuracy is specified as +/-(a percentage of the r a fixed count) at 

23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.

Temperature Coefficient:

  0.1 times the applicable accuracy specification per degree C from 

0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)

Function

Range and 

Resolution

Accuracy

Input 

Protection

61-763

61-765

AC Current

1

0.0 to 660.0A

2.0% + 5

(45Hz to 60Hz)

2.0% + 5

(20Hz to 100Hz)

660A AC

6.0% + 5

(60Hz to 400Hz)

6.0% + 5

(100Hz to 400Hz)

DC Current

0.0 to 660.0A

N/A

2.0% + 5

660A DC

(61-765 only)

AC Voltage

1,2

0.0 to 600.0V

1.0% + 5

(45Hz to 100Hz)

1.0% + 5

(20Hz to 100Hz)

1000VDC / 

750VAC RMS

600.0 to 750.0V

1.5% + 5 

(45Hz to 100Hz)

1.5% + 5 

(45Hz to 100Hz)

0.0 to 750.0V

6.0% + 5 

(100Hz to 400Hz)

6.0% + 5 

(100Hz to 400Hz)

DC Voltage

2

 

0.0-600.0V

1.0% +5

1.0% +5

1000VDC / 

750VAC RMS

600.0 to 999.9V

1.5% + 5

1.5% + 5

Resistance

3

0.0 to 999.9

Ω

1.5% + 5

1.5% + 5

600V DC/AC RMS

1000 to 9999

Ω

Capacitance

0.0 to 999.9µF

5.0% +15

5.0% +15

600V DC/AC RMS

Continuity

0.0 to 999.9

Ω

Audible at < 30

Response time 

500mS

Audible at < 30

Response time 

500mS

600V DC/AC RMS

Frequency

4

20.0 to 400.0 Hz

0.5% + 5

0.5% + 5

1000VDC / 

750VAC RMS

    

*Accuracy stated for crest factor 

 1.5 at full scale and 

 3 at half scale.

PEAK:  

1

For VAC/A AC/DC (45-65 Hz) has accuracy of ±(5% rdg + 15 digits); minimum input for VAC > 10V and for A AC/

DC > 10A; response time > 1ms.

2

Input impedance: 1M

Ω

.

3

Open circuit voltage 

 1.2V DC

4

Frequency Sensitivity: 5V rms on AC VOLTS range (

 5AAC at 20 to 100Hz) (

 10AAC at 100 to 400Hz), Frequency 

can be measured through clamp head.

Overload protection: 1000 AAC, 1000 VDC or 750 VAC RMS

  

12

Dispose of waste electrical and electronic equipment

In order to preserve, protect and improve the quality of environment, protect human health 

and utilize natural resources prudently and rationally, the user should return unservice-

able product to relevant facilities in accordance with statutory regulations. The crossed-out 

wheeled bin indicates the product needs to be disposed separately and not as municipal 

waste.

Disposal of used batteries/accumulators!

The user is legally obliged to return used batteries and accumulators. Disposing used bat-

teries in the household waste is prohibited! Batteries/accumulators containing hazardous 

substances are marked with the crossed-out wheeled bin. The symbol indicates that the 

product is forbidden to be disposed via the domestic refuse. The chemical symbols for the 

respective hazardous substances are 

Cd

 = Cadmium, 

Hg

 = Mercury, 

Pb

 = Lead.

You can return used batteries/accumulators free of charge to any collecting point of your 

local authority, our stores, or where batteries/accumulators are sold. Consequently you comply with 

your legal obligations and contribute to environmental protection.

Warranty Statement:

This tester is warranted to the original purchaser against defects in material and workmanship for 

two years from the date of purchase.  During this warranty period, IDEAL INDUSTRIES, INC. will, 

at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.  

This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, 

alteration, or unreasonable use of the instrument.

Any implied warranties arising out of the sale of an IDEAL product, including but not limited 

to implied warranties of merchantability and fitness for a particular purpose, are limited to the 

above.  The manufacturer shall not be liable for loss of use of the instrument or other incidental or 

consequential damages, expenses, or economic loss, or for any claim or claims for such damage, 

expenses or economic loss.
State laws vary, so the above limitations or exclusions may not apply to you.  This warranty gives you 

specific legal rights, and you may also have other rights which vary from state to state.

Warranty does not cover batteries.

Summary of Contents for 660A TRMS 61-763

Page 1: ...ove the test leads from the circuit prior to removing battery cover Do not attempt to repair this unit as it has no user serviceable parts CAUTION To protect yourself think Safety First Voltages excee...

Page 2: ...nuity Cat IV 600V Cat III 1000V Bright bold backlight Model Specific Features 61 763 and 61 765 models are true rms sensing measures AC DC voltage capacitance AC current and frequency Both models empl...

Page 3: ...Off APO feature must be defeated Relative Mode Press button to enter the Relative mode The symbol is displayed and the value on the display is subtracted and stored as a reference value In the Relativ...

Page 4: ...Voltage AC Voltage DC Voltage Verifying Continuity Verify the circuit is de energized The meter will sense the level of resistance and beep if the resistance is less than 30 to confirm that continuit...

Page 5: ...attery Indication The appears in the display with insufficient voltage for about one hour Then bAtt displays for 5 seconds and unit powers down Indicator duration varies by battery brand Power Supply...

Page 6: ...r should return unservice able product to relevant facilities in accordance with statutory regulations The crossed out wheeled bin indicates the product needs to be disposed separately and not as muni...

Page 7: ...mismas a fin de evitar lecturas falsas Retire los cables de prueba del circuito antes de desmontar la tapa de las bater as No intente reparar esta unidad puesto que no tiene piezas reparables por el...

Page 8: ...ble 61 763 Cat IV 600 V Cat III 1000 V Iluminaci n de fondo brillante y n tida Caracter sticas espec ficas del modelo Los modelos 61 763 y 61 765 son con sensado de valor eficaz rms verdadero medida d...

Page 9: ...imos medidos en un per odo de tiempo mayor que 30 minutos debe anularse la caracter stica de apagado autom tico APO Modo relativo Pulse el bot n para entrar al modo relativo Aparece el s mbolo y el va...

Page 10: ...de CC Verificaci n de continuidad Verifique que el circuito est desenergizado El instrumento detecta el nivel de resistencia y emite un pitido si la resistencia es menor que 30 para confirmar que exis...

Page 11: ...763 y 61 765 Indicaci n de bater a El s mbolo aparece en la pantalla durante alrededor de una hora descargada cuando el voltaje de la bater a es insuficiente Luego aparece bAtt por 5 segundos y la un...

Page 12: ...er el producto fuera de servicio a los establecimientos correspondientes El s mbolo del cubo de residuos con ruedas tachado con una cruz indica que la disposici n final del producto debe realizarse po...

Page 13: ...tures Retirer les fils d essai du circuit avant de retirer le capuchon de pile Ne pas tenter de r parer cet appareil Il ne comporte aucune pi ce r parable par l utilisateur ATTENTION Pour vous prot ge...

Page 14: ...ts R tro clairage lumineux et clair Mesure le courant de 660 c a A 61 763 Caract ristiques particuli res du mod le Les mod les 61 763 et 61 765 sont d tection de valeurs r elles efficaces mesurent la...

Page 15: ...r une p riode de plus de 30 mn il faut invalider la fonction d arr t automatique APO Mode relatif Appuyer sur le bouton pour passer sur le mode Relatif Le symbole est affich et la valeur de l affichag...

Page 16: ...c a Tension c c Circuit ferm Circuit ouvert Mesure de la capacit Appuyer sur Hz pour basculer entre capacit et ohms V rification de la continuit V rifier que le circuit est d sexcit Le multim tre d te...

Page 17: ...eures d utilisation en continu avec une pile alcaline de la pile 61 763 61 765 T moin de d charge Le symbole s affiche pendant une heure environ en de piles pr sence d une tension insuffisante bAtt s...

Page 18: ...s aux installations pertinentes conform ment aux r glements Les poubelles roues barr es indiquent que le produit doit tre vacu s par ment et non avec les ordures municipales Evacuation des piles accum...

Reviews: