IDEAL 61-481 Manual Download Page 9

18

General Specifications

LCD Display:

4000 count maximum reading

Bar Graph Display:

82 segment analog bar graph

Polarity Indication:

Automatic, negative indicated, 
positive implied

Overrange Indication:

“OL” or “-OL”

Low Battery Indication:

“      ” when the battery 
voltage drops below operating 
voltage

Size (WxHxD):

88mm x 180mm x 33.5mm 
(without holster)
94mm x 188mm x 40mm (with
holster)

Sampling:

2 times/sec LCD Display, 
12 times/sec bar graph

Auto Power Off:

Approx. 30 min.

Operating Temperature:

0°C ~ 30°C  (<80% RH), 
30°C ~ 40°C  (<75% RH), 
40°C ~ 50°C  (<45% RH)

Storage Temperature:

-20°C ~ 60°C (0~80% RH) 
when battery removed from 
meter

Temperature Coefficient:

0.15 x (specified accuracy) / 
°C, <18°C or >28°C 

Power Requirements:

9V NEDA 1604, 1EC bf 22, 
J1S 006P

Battery Life:

300 hours (alkaline )

Installation Category:

IEC 1010, 1000V Cat. II, 
600V Cat III

Environmental Conditions
Indoor Use
Maximum Altitude:

2000 Meter

Installation Category:

IEC 1010, 1000V Cat. II, 
600V Cat. III

Pollution Degree:

2

17

Continuity Check

To Verify Continuity:

A continuity test ensures that all circuit connections are intact.  
1.  Plug the black test lead into the COM port and the red test 

lead into the V

Hz port.

2.  Set the rotary switch to the 

position.

3.  Press the blue button until       is shown in the display.
4.  Connect the test leads to the circuit to be measured.  The 

buzzer will sound if the resistance of the circuit measured is
lower than 30

.

Accessories

For AC Current Clamp (61-450):

1.  Plug the black test lead into the COM port and the red test 

lead into the V

Hz port.

2.  Remove the probe tips from the end of the leads.
3.  Attach the leads to the current clamp. (polarity will not effect

reading)

4.  Set the rotary switch to the V position.
5.  Push the blue button until 

AC

is shown on the display.

6.  Snap the jaw of the current clamp around one of the current 

carrying conductors.

Hz

True RMS

Circuit Connection:

C

˜

Summary of Contents for 61-481

Page 1: ...Hz True RMS 1 7 4 2 3 5 6 Symbols in this Manual This symbol indicates where cautionary or other information is found in the manual Fuse Battery Refer to Figure 1 and to the following numbered steps...

Page 2: ...mode also changes the full scale range of the original voltage or cur rent mode WARNING 1 DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS Voltage is not to exceed 1000 Volts Resistance Capacitance...

Page 3: ...alarm 15 seconds before the meter automatically turns the power off To disable the auto power off function power up the meter while pressing either the range or Hz switch True RMS AC Volt Range Resolu...

Page 4: ...test lead into the mA or A port 2 Set the rotary switch to the mA or A position 3 Push the blue button until AC is shown on the display 4 Connect the meter in series with the load or circuit 5 Measure...

Page 5: ...load or circuit 5 Measure Frequency or RPM Overload Protection 600V rms Less than 50Hz the sensitivity is 1 5V DC Current Range Resolution Max Accuracy Voltage Display Burden 40mA 10 A 40 00 0 6 2 20...

Page 6: ...the device being tested contains no voltage 5 Press the range button to select the proper range of the meter 6 Measure resistance 11 Frequency with Hz Switch Function Range Sensitivity Accuracy AC Vol...

Page 7: ...00 Meter indicates actual resistance 3k Multiply meter display reading by 1 000 to acquire actual resistance 30k Multiply meter display reading by 1 000 to acquire actual resistance 300k Multiply mete...

Page 8: ...ress the blue button until is shown on the display 5 Connect the test leads to the diode Normally the forward voltage drop of a good silicone diode is shown between 400V and 90V If the diode under tes...

Page 9: ...Conditions Indoor Use Maximum Altitude 2000 Meter Installation Category IEC 1010 1000V Cat II 600V Cat III Pollution Degree 2 17 Continuity Check To Verify Continuity A continuity test ensures that al...

Page 10: ...ent The 61 480 is powered by one 9V battery 1 Remove the test leads from the front terminals and turn the meter off 2 Remove the screw from the battery cover and lift to remove 3 Lift battery box and...

Reviews: