14
SEL Button
Lead Warning
Fuse Warning
Lead Warning:
When inserting the test
lead into any amperage input terminal, but
the rotary function switch
IS NOT
set to the
correct relative amperage position, the meter
will beep at 3Hz, LCD will display ”
LEAd
“
and “
.
”, flashes at 3Hz. If any amperage
function is selected first, but the test lead
IS
NOT
in the relative amperage input jack,the
meter will also beep at 3Hz and the LCD will
display “
LEAd
” and “
.
”, flashes at 3Hz.
Fuse Notification:
The test leads
CANNOT
be short circuited or used for
measuring while testing the fuse.
1. If the 600mA/1000V fuse is blown,
setting the rotary switch to the “mA”
or “uA” setting, the LCD will display
“
FUSE
” and “
.
”, and the buzzer
will beep continuously at the same time.
2. If the 11A/1000V fuse is blown,
setting the rotary switch to the “A”
setting, the LCD will display “
FUSE
”
and “
.
”, and the buzzer will beep
continuously at the same time.
The SEL Button allows the user to toggle between multiple
functions when the function dial is used to select a specific
function. This can include but is not limited to toggling between
degrees F and C, AC and DC voltage or current, continuity,
resistance, capacitance and diode measurements.