background image

 
 
 
 
 

Selection of Language, Temperature Indication, Factory Settings 

The following 8 languages are available: English, German, Dutch, Swedish, Italian, Spanish, French and Portuguese. The factory setting is 
English. 

• 

  Press and hold the key          for 2 seconds: The language 

ENGLISH

 

is blinking. Select your language with the keys “

-

” or “+”

 

• 

  Press the key            briefly: Indication 

CELSIUS

 or 

FAHRENHEIT

 is blinking. Select 

CELSIUS

 or 

FAHRENHEIT

 

with the keys “

-

” or “+”

 

• 

  Press the key            briefly: Indication 

RESET TO FACTORY SETTINGS

 or 

KEEP USER SETTINGS

. Select 

RESET TO FACTORY

  

 

SETTINGS

 or 

KEEP USER SETTINGS 

with the keys “

-

” or “+” . Press the key  

          briefly to return to the functional program. 

 

 

Example: 
 
 

 

Select the language 

Select the temperature indication 

 
 

 
 
 
 
 
 

Overview of the function programs 

• 

 

To each function program, values for temperature and air volume are assigned.  The following programs are available. The bold letters are 
the keywords, which are permanently indicated in the display 

 

 

 

                                                        

 

 

 
  

                                          

 

 

 
 

  

 

 

      

 

             

 

 

 

 

 

 

 

 

  

 

 

   

 

        

 

 
 

  

 

 

     

 

             

 

 
 

   

 

 

    

 

          

 

 
 

   

 

 

      

 

              

 

 
 

   

 

 

         

 

 
 
 
Selection of the function programs 

The keyword of each program is indicated during approx. 2 seconds in the display.  If the program name contains of more than 10 digits, the 
text begins to move.  After two complete turns, the keyword remains indicated in the display. 

 
Press the key            

briefly:  The keyword of the program is blinking.  Select the required functional program with the keys “

-

” or “+”.

 

 
 
 
 
 
 
 
 
 

Heat Elite  

Plus LCD

 

         FREE 

Setting 

180ºF, Air volume 5 

WELDING

 

660ºF, Air volume 3 

SHRINKING 

840ºF, Air volume 3 

FORMING 

930ºF, Air volume 4 

SOLDERING 

1200ºF, Air volume 3 

DRYING 

1200ºF, Air volume 5 

PAINT 

 

800ºF, Air volume 5 

Summary of Contents for 46-204

Page 1: ...materials must be checked before using the hot air tool Heat may reach materials which are not visible Do not aim the stream of hot air at the same spot for extended periods Cause burns Do not touch the heat nozzle and adaptor when hot as they can cause burns Never use the tool as a hair dryer It gets much hotter than a hairdryer Do not point the hot air flow in the direction of people or animals ...

Page 2: ...r 60 Sn 40 Pb and special silver solder Desolder of SMD components Soldering of cable shoes Unsoldering of soldered joints Paint stripping Stripping of all oil and lacquer even in thick layers from furniture and paneling gutters banisters and windows Heat the layer of paint until blisters form then remove cleanly with a paint knife paint scraper or wire brush For windows use glass protecting adapt...

Page 3: ...ttings in use Main switch in position I Example Attention Heating starts immediately Heat Elite Plus LCD Operating Principles Individually adjustable values Temperature Indicated value 50 C respectively 90 F Maximum value 650 C respectively 1200 F At the program FREE SETTING the entire range of 80 C 650 C respectively 180 F 1200 F is available Air volume 7 0 17 5 cfm in 5 steps Memory Function Eac...

Page 4: ...ge Select the temperature indication Overview of the function programs To each function program values for temperature and air volume are assigned The following programs are available The bold letters are the keywords which are permanently indicated in the display Selection of the function programs The keyword of each program is indicated during approx 2 seconds in the display If the program name ...

Page 5: ...p Adapter Pressure roller Solder Reflector Cat No 46 952 Cat No 46 955 Cat No 46 956 Cat No 46 953 Only genuine IDEAL adapters may be fitted onto the Heat Elite Plus LCD When fitting an adaptor it is strongly recommended to switch off the Heat Elite Plus LCD Attention Do not touch the adaptors they are hot Always use pliers Any hot item must be placed on a fire proved surface example a metallic sh...

Page 6: ...aid and with our examination shall disclose to our satisfaction to have been defective This warranty shall not apply to any model which has been altered or repaired outside the factory in any way so as to affect its operation nor which has been subject to misuse negligence accident or installed or operated in any other way than in accordance with our instructions nor shall this warranty extend to ...

Reviews: