background image

#33-410

RF Coax Crimp & Compression Kit

Instruction Manual

45-526 2-Step Coax Stripper instructions 

1.  Initially set slide bar on top of stripper to size larger than cable 

  you are to strip. (Ex. Stripping RG-59/62 start with bar on “6”). 

  Insert cable and rotate stripper approximately 10 times. Move bar 

  to correct cable size you are stripping and rotate another ten 

  times. This gradual increase in strip depth eliminates any twisting 

  of braid and increases the life span of the blades.

2.  Open stripper up and remove cable. Twist off stripped piece and 

  see if adjustment is needed. Deepen or lessen the strip depth of 

  individual blades with hex wrench stored inside handle. Clockwise 

  turning of hex inserts will deepen blade cut and counter-clockwise 

  and will lessen the depth. Make gradual adjustments for each strip 

  one at a time. Then continue to the next strip step. Retry until proper strip is obtained. Make sure 

  no debris is in the blades of the stripper, this will interfere with proper adjustment of tool.

30-793 OmniSeal™ XL Compression Tool Instructions 

Step 1

•  Step strip cable (Fig. 1)

Step 2

•  Push connector onto cable.

Step 3

•  (Fig. 2) with the tool in the open position (tool handle on the bottom),

  place the cable and connector into the tool opening over the plunge

  tip. Apply a downward pressure on the able and connector to allow the

  split jaws to secure the cable. The cable and connector will now be in

  position between the plunger tip and the split jaws.

Step 4

•  (Fig. 3) To compress the connector, close the tool handle completely,

  insuring the connector seelve is fully compressed.

Note: This tool has been specifically designed to assemble the following

compression connectors without tool adjustments: F-type, mini F-type, 

RCA and mini RCA IDEAL connectors. 

Warning! This tool should not be used on live circuits. It is not protected

against electrical shock! Always use OSHA/ANSI or other industry 

approved eye protection when using tools. This tool is not to be used for 

purposes other than intended. Read carefully and understand instructions 

before using this tool. 

1

4

9

1

4

9

1

4”

1

4”

Figure 1

Insert Cable and Connector

Figure 2

Compress Connector

Figure 3

Reviews: