![IDEAL 320 Series Instructions Manual Download Page 10](http://html.mh-extra.com/html/ideal/320-series/320-series_instructions-manual_616689010.webp)
10
Resistance (Ohms)
Range
Resolution
Accuracy
Max. Display
600
Ω
0.1
Ω
600.0
6K
Ω
1
Ω
±(0.7% reading
6.000
60K
Ω
10
Ω
+ 2 digits)
60.00
600K
Ω
100
Ω
600.0
6M
Ω
1K
Ω
6.000
60M
Ω
10K
Ω
60.00
Open Circuit Voltage:
-1.3V approx.
To Measure Resistance:
1. Turn the power off to the circuit or device that is to be
measured and discharge all capacitors before attempting a
measurement.
2. Plug the black test lead into the COM port and the red test
lead into the Hz V
Ω
µA port.
3. Set the rotary switch to the
Ω
position.
4. For correct reading, ensure that the device being tested
contains no voltage.
5. Connect test leads across the resistor or circuit to be measured.
6. Measure resistance.
Circuit Connection: