![Ideal-Standard ALTO ECOTHERM A4740AA Installation Instructions Manual Download Page 7](http://html1.mh-extra.com/html/ideal-standard/alto-ecotherm-a4740aa/alto-ecotherm-a4740aa_installation-instructions-manual_617249007.webp)
+
a
b
The thermostatic mixing valve must be installed in such a position that maintenance of the TMV and its
valves and the commissioning and testing of the TMV can be undertaken.
Two 15mm inlet pipes need to be run at 150mm
centres which will have been identified as the loca-
tion of the shower fitting and cut two holes of dia-
meter 25-30mm in the wall board. We recommend
leaving 50mm of pipe protruding at this stage.
Place wall plate over pipework and onto
the wall surface. A spirit level can be
placed on the flats of the wall plate to
ensure the level. Once at the correct
position the two fixing holes can be
marked. Drill two holes to suit appropri-
ate wall fixings.
7
4
INSTALLATION GUIDE
2
IMPORTANT
BEFORE CONNECTION, FLUSH WATER
THROUGH PIPEWORK TO REMOVE ALL
DEBRIS ETC. WHICH COULD DAMAGE
THE VALVE MECHANISM
1
HOT water
supply pipe
50mm
150
COLD water
supply pipe
2
3
Flats on mounting plate
Mark the locations
Fig. 5 SLIDING RAIL – CATEGORY 5 HOSE RETAINING
Note:
Fixing holes in
bracket are at 65mm
centres.