INTRODUCTION

The Vogue Max System IE is a wall mounted, room sealed, condensing system boiler, featuring full sequence automatic spark 

ignition and fan assisted combustion.

Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point 

through a plastic waste pipe at the base of the boiler.  A condensate ‘plume’ will also be visible at the flue terminal.

SAFETY

Current Gas Safety (Installation & Use) Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in 

accordance with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition 

of I.S. 813 “Domestic Gas Installations”, the current Building Regulations and reference should be made to the current ETCI 

rules for electrical installation.

It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.

FOR ANY QUERIES PLEASE RING THE

IDEAL CONSUMER HELPLINE : 00353 (0)1 961 7700

NOTE. BOILER RESTART PROCEDURE - 
To restart the boiler, press “RESTART” hot key located below the colour screen.  The appliance will now repeat 

the ignition sequence if a heat demand is present.

Summary of Contents for VOGUE MAX SYSTEM 26IE

Page 1: ...cation that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices...

Page 2: ...2...

Page 3: ...nchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ens...

Page 4: ...must be installed by a Gas Safe Registered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance...

Page 5: ...en supervision or instructions concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance In cases of rep...

Page 6: ...R OR ROOM THERMOSTAT OFF 39O C TO CYLINDER ON 39 C min max on off A B H D A Boiler Status B Burner On indication Legend C Hot Keys D Central Heating Temp Control E On Off Control F Pressure Gauge G G...

Page 7: ...aller 01482 498663 EXIT RESTART Reset the boiler and the ignition sequence will be repeated OPERATION Central Heating With the external heating controls calling for heat the off on control E set to on...

Page 8: ...rature for all outside weather conditions TO SHUT DOWN THE BOILER Set the off on switch E to off TO RESTART THE BOILER Repeat the procedure detailed in To light the boiler page 7 Set the off on contro...

Page 9: ...he filling loop Press RESTART hot key on the control panel to restart the boiler If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Instal...

Page 10: ...To unblock a frozen condensate pipe 1 Follow the routing of the plastic pipe from its exit point on the appliance through its route to its termination point Locate the frozen blockage It is likely tha...

Page 11: ...LEAKS WITH A NAKED FLAME CLEANING For normal cleaning simply dust with a dry cloth To remove stubborn marks and stains wipe with a damp cloth and finish off with a dry cloth DO NOT use abrasive cleani...

Page 12: ...ugh the following guide to identify any problems external to the boiler prior to requesting a service engineer s visit Should the problem be found to be other than with the appliance we reserve the ri...

Page 13: ...tat are switched on Check batteries in programmable room stats Ensure that the mains supply to the boiler is switched on and that no trips have operated in the consumer unit FAULT FINDING If a fault o...

Page 14: ...to the on position to switch the boiler on MENU OFF Indicates that the boiler is either heating the radiators or the hot water cylinder MENU 60O C ON Indicates that either the timer is off or the room...

Page 15: ...Boiler is providing central heating and radiator temp is 60 C Indicates that central heating timer or room stat is off Indicates that the boiler is switched off Move off on switch E to the on position...

Page 16: ...C and the boiler is running to protect itself from frost damage MENU BOILER FROST PROTECTION ACTIVE SWITCH OFF TEMPERATURE 19O C Indicates that a service is due To reset the service time refer to page...

Page 17: ...entral Heating frost protection turn the On Off switch E to the Off position This screen will be shown MENU OFF To switch the boiler on turn the On Off switch into the On position E This screen will b...

Page 18: ...MENU and the following screen will be displayed Press select and a screen similar to the following will be displayed Press EXIT twice to return to normal operation EXIT SELECT MENU SERVICE COMPANY NAM...

Page 19: ...til the following screen is displayed Press SELECT and the following screen is displayed Press MENU SHOW EFFICIENCY LEVEL HOT WATER PREHEAT ON OFF SERVICE COMPANY PHONE NUMBER SERVICE COMPANY NAME MAX...

Page 20: ...ucts The right is therefore reserved to vary specification without notice H E A T I N G The code of practice for the installation commissioning servicing of central heating systems Manufactured under...

Reviews: