IMPORTANT:
Ensure the wall where the boiler will be is
flat.
The wall mounting template is located on the internal
protective packaging. The template shows the position of the
fixing and rear flue centre holes for a standard installation.
1. Secure the template into the required position. Ensure it
is square by hanging a plumbline.
2. If fitting a side flue, extend the flue centreline onto the
side by 155 mm on a standard wall fix or 200 mm if using
a stand-off bracket.
3. Mark the following on to the wall:
a The selected group of wall mounting screw holes.
b. The centre position of the flue duct. Marking both the
centre and the circumference of the flue duct.
4. Remove the template plate from the wall.
2.3 WALL MOUNTING TEMPLATE
2.4 PREPARING THE WALL
1. Check all of the hole positions before drilling.
2. Cut the flue hole with a 127 mm core boring tool, ensure
the hole is square to the wall.
3. Drill the 2 mounting holes with a 7.5 mm / 8 mm masonry
drill and insert the plastic plugs provided.
4. Locate 2 No.14 x 50 mm screws in the wall mounting
plate (one at each side, in any of the 3 holes provided at
each side) and screw home. Ensure mounting bracket is
level.
2.5 FITTING THE WALL MOUNTING PLATE
1. Lift the boiler onto the wall mounting plate and locate it
over the 2 tabs.
2.6 MOUNTING THE BOILER
1. Screw the wall mounting plate to the wall using 2 wall
plugs fitted previously with the 2 screws provided.
2. Choose one of the 2 sets of slots in left and right bank.
Ensure that at least one of the screws is fitted into a top
slot and the mounting bracket is level.
“A”
Extended centre line
155
(200)
X
Section
through wall
Side flue only
127 mm diameter hole
Rear flue only
127 mm diameter hole
esp9496
Example of fixing
Refer to Section
2.8
WARNING:
Ensure that, during the cutting
operation, masonry falling outside of the building
does not cause damage or personal injury.
16
Installation and Servicing
Section 2 - Installation
INST
ALLA
TION