1.5.2
Fire extinguisher and first aid
Place a first aid kit and fire extinguisher near the unit.
Periodically make sure that the fire extinguishers are charged and that the way to use
is clear.
In case of fire, use it according to the regulations in force and contact the fire
brigade.
Check periodically that the first aid kit is complete.
Make sure you have first aid phone numbers nearby.
The supply of fire extinguisher and first aid kit is the responsibility of the owner of the building on which
the unit is installed.
1.5.3
Warnings for checks and maintenance
Apply a sign with the words: "UNDER MAINTENANCE" on all sides of the unit.
Check the unit carefully by following the list of operations in this manual.
1.5.4
Safety tags
Generic alarm Electric voltage Danger of burns Moving parts Cut wounds
2
PRODUCT DESCRIPTION
KERS recuperators are designed to ventilate apartments, hotels, bars and any other civil, residential and
commercial environment in a controlled manner.
The unit is equipped with a very high efficiency ceramic exchanger which allows to introduce fresh air into the
room and to recover heat from the previously expelled exhausted air.
KERS recuperators combine state-of-the-art technical solutions (ceramic recuperator with 91% efficiency) with a
pleasant aesthetics. The exposed installation is aesthetically pleasing thanks to the elegant external covers.
KERS is designed to be mounted in external walls with thickness from 300 mm to 570 mm on KERS 25. Special
extensions allow to overcome greater thicknesses (see paragraph 9.5).
The low air speed avoids the annoying drafts present in traditional air conditioning systems and guarantees
maximum environmental comfort.
The exclusive use of components of the highest quality in the aeraulic and electrical parts puts the KERS units at
the highest levels of the state of the art, in terms of efficiency, reliability and sound power emitted.
2.1
STRUCTURE AND OPERATION
The unit consists of: a ventilation unit, a recuperator, two filters, an external protection hood and a telescopic
duct. The length of the duct can be adjusted by sliding the duct section facing the room, inside the duct section
facing outwards.
The two filters and the exchanger are inserted in the telescopic duct. The filters purify the new air and prevent
the entry, from the outside, of objects that can damage the exchanger or the fan.
The unit is equipped with a non-volatile memory clock, which generates an audible signal every 90 days of
operation to remind you to change or clean the filters. The signal repeats every 5 minutes until maintenance is
completed. After maintenance, press the ON-OFF button on the remote control for 10 seconds to reset the clock:
a long signal confirms that the clock has been reset.
Each time the ON-OFF button is pressed for 10 seconds, the non-volatile memory clock resets.
The heat exchanger recovers the heat of the exhaust air to heat the air introduced into the room. It is provided
with a cord that facilitates its removal from the unit and with an insulation that also acts as a sealing gasket.
A shutter closes automatically when the appliance is in stand-by, to prevent the passage of unwanted air
currents.
The ventilation unit must be installed in places where it is not possible to enter water or other substances that
could damage its components. The fan must be on the inside of the wall.