Ideal Boilers mini C24 Installation And User Manual Download Page 2

1

DIGITAL PROGRAMMER
Installation instructions

WARNING

The installation of this device must be carried out by a

qualified person who will be responsible for observing

the current Regulations.

ALWAYS switch off and disconnect the electricity supply

to the appliance before installing the programmer.

Switching the boiler on/off switch ‘off’ may leave a live

feed to the boiler.

To install the programmer:

1 Remove the screws A and lift off the boiler front panel.

A

A

2 Remove the screws B.
3 Loosen the screws C.

C

B

B

C

4 Remove the side panels or move the lower part of the side

panels and pull the control panel.

When completely pulled out, the panel can rotate 45°

downwards to facilitate access to the internal parts.

5 Remove the screws D and remove the service panel
6 Remove the screws E and remove the control panel lid.

E

D

Control panel lid

Service panel

E

7 Squeeze the hooks that hold in place the infill panel F and

remove it.

8 Fit the programmer.

F

9 Connect the programmer to the main control p.c.b.

referring to the following diagram.

rd

bk

wh

gn

bk = black

wh = white

rd = red

gn = green

Programmer

(rear view)

Control p.c.b.

10 Re---assemble the boiler following the steps 1 to 6 in

reverse order.

11 Operate the boiler and check for its correct operation.

Summary of Contents for mini C24

Page 1: ...ny part of this appliance use only spare parts that you can be assured conform to safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers http waterheatertimer org Hagar timers and manuals html ...

Page 2: ...the side panels or move the lower part of the side panels and pull the control panel When completely pulled out the panel can rotate 45 downwards to facilitate access to the internal parts 5 Remove the screws D and remove the service panel 6 Remove the screws E and remove the control panel lid E D Control panel lid Service panel E 7 Squeeze the hooks that hold in place the infill panel F and remov...

Page 3: ...g 3 Activating the timed settings Set the mode selector switch B to the AUTO position shown in Fig 4 The current time appears in the display The ON OFF display A indicates the current state of operation according to the settings B Fig 4 Note when the mode selector switch B is in the AUTO position and the boiler is switched off at the fused spur isolation switch the display A indicates only the OFF...

Page 4: ...he time display H are flashing Set the mode selector switch B to the position and press the buttons E or F until the current time appears in the display H Press the day selection button corresponding to the current day considering that button 1 Monday button 2 Tuesday and so on The clock starts by moving the switch B to the AUTO position Setting example shown in Fig 7 Current time 16 30 day Thursd...

Page 5: ...orce constantly on or off the timer operation set the mode selector switch B to the TIMER position The symbols shown in Fig 11 appear on the display Fig 11 The operation can be switched permanently on or off by pressing the button G and leaving the switch B in the TIMER position To force a timed delay on or off operation set the mode selector switch B in the TIMER position Set the time delay by pr...