background image

3

Mexico Super RS440-470 - 

Users

Note.

Grille assembly not shown, for clarity

2

BOILER CONTROLS

To Light the Boiler.

Refer to Frame 2

If a programmer is fitted refer to separate instructions for the
programmer before continuing.

1.

Check that the electricity supply to the boiler is OFF.

2.

Open the control panel drop-down door and ensure that the
thermostat knob (G) is in the OFF position.

3.

Switch ON the electricity supply to the boiler and check that
all external controls, e.g. room thermostat etc., are ON.

4.

Set the boiler thermostat knob (G) to position 6. The pilot
solenoid valve should open and the intermittent spark
commence, continuing until the pilot is established. The
main burner will then cross-light smoothly.

Winter conditions (i.e. central heating and domestic hot
water).

 The thermostat should  be positioned at setting 5 or 6.

Summer conditions (i.e. domestic hot water only).

 The

thermostat should be positioned at setting 2.

These settings are offered for general guidance only and other
settings may be found preferable, dependent upon the type of
system installed or as recommended by the installer.

To Shut Down the Boiler

1. For short periods

Turn the boiler thermostat knob (G) to OFF. When heating is
again required, restore the knob to its original setting.

2. For longer periods

a.

Turn the boiler thermostat knob (G) to OFF.

b.

Switch the electricity supply to OFF.

Frost Protection

If no frost protection is provided and frost is likely during a short

absence from home, leave the heating controls (if fitted) at a

reduced temperature setting.
For longer periods, the entire system should be drained -

including the domestic water supply.

LEGEND
A.

Gas control valve.

B.

Burner pressure test point.

C.

Main burner pressure adjuster.

D.

Inlet pressure test point.

E.

Gas service cock.

F.

Sightglass.

G.

Boiler thermostat knob.

H.

Main burner 'On' neon.

J.

Overheat thermostat reset button
(optional).

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in
your 

Benchmark 

Log Book.  You can check your installer by calling CORGI direct on 01563 72300

THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS

Caradon Ideal Limited

 is a member of the Benchmark initiative and fully supports the aims of

the programme.  Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.

If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if

fitted) ONLY. The mains supply should be left switched ON,

with the boiler thermostat left in the normal running position.

Control of Water Temperature

1.

Set the boiler thermostat knob (G) to give the required

temperature for central heating.

2.

The boiler thermostat automatically switches the main

burner OFF and ON to maintain the selected temperature.

To Relight the Boiler

Repeat the procedure 1 - 4 detailed in 'To light the boiler'.

Boiler Overheat Thermostat

(Fitted for sealed systems only)

For a boiler fitted with a safety 'cutout' thermostat:  this
thermostat will shut down the boiler in the event of overheating.

Should this occur, allow the boiler to cool, press the reset

button (J) on the overheat thermostat then relight as detailed in
steps 1-4 under 'To light the boiler'.
If the 'cutout' condition persists turn off the boiler and consult a
CORGI registered installer or in IE a competent person.

Loss of System Water Pressure

(Boilers fitted with the Overheat Thermostat Kit only)

If the red arrow on the system pressure gauge is set above
zero and the system pressure is seen to fall below this value

over a period of time then a water leak is indicated.  In this
event a CORGI registered installer or in IE a competent person
should be consulted.

DO  NOT  FIRE  THE  BOILER  IF  THE  PRESSURE  HAS
REDUCED  TO  ZERO  FROM  THE  ORIGINAL  SETTING

Escape of Gas

Should a gas leak or fault be suspected, contact your gas

supplier 

without delay.

Do NOT search for gas leaks with a naked flame.

200941-1.p65

3/3/2004, 10:26 AM

39

Reviews: