To shut down the boiler

1. For short periods

Set the mains ON/OFF switch (A) to OFF

2. For longer periods

Set the mains ON/OFF switch (A) to OFF, and switch the
electricity supply to OFF. For longer periods the entire
system should be drained.

To relight the boiler

Repeat the procedure detailed in 'To light the boiler'.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting. For longer periods, the entire
system should be drained.

If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
fitted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.

Boiler overheat thermostat

This thermostat will shut down the boiler in the event of

overheating. Should this occur a fault code 

 

 will be

displayed. Press the reset button (D) and the boiler will relight.

If the fault recurs, turn off the boiler and consult a CORGI
registered installer.

Flame failure

Should this occur a fault code 

 will be displayed.

Press the rest button (D) and the boiler will relight.
If the fault recurs, turns off the boiler and consult a CORGI
registered installer.

Loss of system water pressure

The gauge (see illustration below) indicates the central heating
system pressure. If the pressure is seen to fall below the
original installation pressure of 1-2 bar over a period of time
then a water leak is indicated. In this event a CORGI registered
installer should be consulted.

DO NOT FIRE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Condensate Drain

The condensate drain must not be modified or blocked.

Blockage of the condensate drain, caused by debris or freezing,
can cause automatic shutdown of the boiler.

If freezing is suspected and the pipe run is accessible an
attempt may be made to free the obstruction by pouring hot
water over the exposed pipe and clearing any blockage from the
end of the pipe. If this fails to remedy the problem the
assistance of a CORGI registered installer should be sought.

Escape of gas

Should a gas leak or fault be suspected contact your local gas
supplier without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
CORGI registered installer.

Summary of Contents for istor HE260

Page 1: ......

Page 2: ...appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes I...

Page 3: ...o the central heating if required Note In normal operation the control unit display G will show codes Standby no demand for heat CH being supplied DHW being supplied to reheat the cylinder During igni...

Page 4: ...is controlled by thermostatic mixer within the tank module see illustration below Pull off the lower door from its locating pegs and adjust the mixer valve to the required DHW delivery temperature IM...

Page 5: ...ight If the fault recurs turns off the boiler and consult a CORGI registered installer Loss of system water pressure The gauge see illustration below indicates the central heating system pressure If t...

Page 6: ...e default programme is as the CH programme above changing the times again is as above To save the desired times move the right switch to RUN 4 To delete a switching time on CH or DHW Set the right sli...

Page 7: ...the left sliding switch in the AUTO position will change the programmed switching until the next programme time is reached i e this function will turn an ON period to OFF and vice versa A 1 or 2 will...

Page 8: ...P O Box 103 National Ave Kingston upon Hull HU5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 Caradon Ideal Limited is a member of the Benchmark initiative and fully sup...

Reviews: