Classic 

 SE FF 

Users

2

TO LIGHT THE BOILER.

REFER TO FRAME 1

If a programmer is fitted, refer to separate instructions for the
programmer before continuing.

1.

CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.

2.

Open the controls access door by hinging downwards.

3.

Ensure that the gas inlet cock (D) is OPEN.

4.

Press the overheat reset button (E), located as shown in
Frame 1.

5.

Ensure that the mains on/off switch (C) is in the OFF
position.

6.

Switch ON the electricity supply to the boiler. Check that all
external controls, e.g. room thermostat etc., are ON.

7.

Turn the boiler thermostat knob (B) to position 6 and the
mains on/off switch (C) to ON.  After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.

8.

Close the controls access door.

CLASSIC SE FF  (NATURAL GAS MODELS ONLY)

INTRODUCTION

It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
the boiler.

CURRENT GAS SAFETY (INSTALLATION &
USE) REGULATIONS OR RULES IN FORCE.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer or in IE
a competent person, in accordance with the above regulations.

ELECTRICITY SUPPLY

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz. 

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.

IMPORTANT NOTES

a.

This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.

b.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

c.

The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.

d.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.

e.

Where the boiler is fitted with a Vertex flue system with a
draught diverter in the loft the loft space MUST NOT be used
as a dwelling area.

f.

Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.

MINIMUM CLEARANCES

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given below MUST be complied with
in order to maintain the safe running of the boiler .

Above the boiler

100 mm

(4")

At each side of the boiler

5 mm

(

1/4

")

Underneath the boiler

100 mm

(4")

In front of the boiler

75 mm

(3")

CAUTION.  To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance care should be taken when handling edges of sheet steel components

Models

G.C. Appliance No.
White

Silver

Classic SE9 FF ............ 41 395 30 ....... 41-397-63
Classic SE12 FF ......... 41 395 31 ....... 41-397-64
Classic SE15 FF ......... 41 395 32 ....... 41-397-65
Classic SE18 FF ......... 41 395 33 ....... 41-397-68
Classic SE21 FF ......... 41 395 34 ....... 41-397-69
Classic SE24 FF ......... 41 395 35 ....... 41-397-70
Classic SE30 FF ......... 41 395 36 ....... 41-397-71