Concord CXSi 110-180 - 

User's

 

Guide

TO SHUT DOWN THE BOILER

For short periods

Turn the boiler off at the time clock or system controls. Wait 6
min. and then turn the boiler control thermostat knob (1) to OFF.
Note the frost warning below.

For long periods

Turn the boiler off at the time clock or system controls. Wait for
6 min. and then turn the boiler control thermostat knob (1) to
OFF. Note the frost warning below.

TO RELIGHT THE BOILER

After short periods

Switch on the time switch or system controls and turn boiler
thermostat knob (1) to the required setting. The boiler will light
providing the external controls are calling for heat.

After long periods

Follow the lighting instructions above. Refill the system if it has
been drained.

FROST WARNING

If frost is likely, leave the boiler thermostat at position 6 and do
not turn off the gas cock. This will enable the built-in frost
thermostat  to protect the boiler. Note that this may not protect
remote parts of the system, in which case a separate frost
thermostat should be fitted or the system drained and the boiler
shut down, as for Long Periods.

1.

Check that the boiler thermostat knob (1) on the control box (2)
is OFF.

2

. Ensure that the mains gas inlet cock (3) is open (groove in the

square head in line with the gas pipe).

3.

Press in and release the overheat thermostat button (4).

4.

Switch on the electrical supply to the boiler.

5.

Ensure that all system controls (time switch, system controls
etc.) are calling for heat.

6.

Turn the boiler thermostat knob (1) to position 6.

7

. The boiler will light at Low rate and the Boiler On light (5) will be

illuminated. If it does not light the Lockout light  (6) will be
illuminated. Press in and release the Lockout button (7). The
controls will reset and attempt to relight.

8.

The burner will remain at Low rate for about 3 minutes before
going to High rate.

9.

Set the boiler thermostat knob and the system controls to the
required settings.

TO LIGHT THE BOILER

CONTROL PANEL LIGHTS

1.

The Boiler On light (5) is illuminated while the boiler is firing.

2.

If the Overheat light (8) is lit, pull off the casing lower front panel
and press in the overheat reset button (4).  Replace the lower
front panel and follow the boiler lighting instructions above. If the
overheat condition persists consult a CORGI registered installer.

3.

If the Lockout light (6) is lit press in the Lockout reset button (7).
If the lockout condition persists consult a CORGI registered
installer.