 Classic SE Propane FF - 

Users

1

BOILER CONTROLS

LEGEND
Sightglass
Thermostat knob
Mains on/off switch
Gas service cock (shown in the

OPEN position)

Overheat thermostat reset button

View inside boiler controls area

Boiler Overheat Thermostat

The boiler is fitted with a safety 'cutout' thermostat. This will shut
down the boiler in the event of overheating. Should this occur allow
the boiler to cool, press the reset button (E) then relight as detailed
in steps 1-8 in 'To light the boiler'.

If the cutout condition still persists turn off the boiler and consult a
CORGI registered installer or in IE a competent person.

Control of water temperature

1. Adjust the boiler thermostat (B) to give the required temperature

for central heating.

2. The boiler thermostat automatically switches the main burner

OFF and ON to maintain the selected temperature.

To relight the boiler

Repeat the procedure 1 - 8, detailed in 'To light the boiler'.

Loss of system water pressure

Boilers fitted with Classic Sealed System Units only

If the red arrow on the unit pressure gauge is set above zero and
the system pressure is seen to fall below this value over a period
of time then a water leak is indicated.  In this event a CORGI
registered installer or in IE a competent person should be
consulted.

DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Escape of gas

Should a gas leak be suspected contact your local gas supplier
without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a CORGI
registered installer or in IE a competent person.

THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS,
STATUTORY INSTRUMENT 1994, NO. 1886, AND AMENDMENTS
1996, IMPOSE CERTAIN LEGAL OBLIGATIONS ON GAS USERS.

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in
your  Benchmark  Log Book.  You can check your installer by calling CORGI direct on 01563 72300

THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS

Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the aims of
the programme.  Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.

Changing gas cylinders

a. Ensure that the replacement gas cylinder is the correct one for

the installation.

b. Extinguish any fire, flame or source of ignition (including

cigarettes, pipes and pilot lights) before changing the gas
cylinders.

c. Change cylinders with caution.

d. Ensure that the gas cylinder valve(s) is/are closed before

disconnecting an empty cylinder or before removing any plastic
cap or plug on the outlet connection of the replacement cylinder.
Never use tools on cylinder valves, hand wheels or levers.

Note. 

Cylinders with threaded connections have a left hand

thread.  For cylinders with self-sealing clip-on valves, ensure
that the regulator tap is closed before disconnection.

e. Ensure that the replacement cylinder connections are gastight.

Any leaking  vapour will have a distinctive odour.  Test by using
leak detection solution around the connections - bubbles will
form if vapour is leaking.

NEVER USE A NAKED FLAME

f.

It is essential that the correct pressure regulator, with the correct
pressure setting and capacity for the installation, is used in
accordance with the manufacturer's instructions.

g. In the case of a connection on a pressure regulator or gas

appliance which relies upon a sealing washer to maintain a
gastight joint, it is essential to check that the washer is
present and that it is sound and correctly positioned prior to
making the connection.  Where the connection relies on a
metal-to-metal seating or bullnose connection to obtain a
gastight joint, it is essential that the mating surfaces be
clean and undamaged.
Under no circumstances should a damaged valve or
connection be used.

h. Where connections are designed to be tightened with a

spanner, it is essential that a spanner of the correct size is
used and that the union is firmly tightened - hand tightness is
not sufficient.

When self sealing valves are incorporated in a gas cylinder,
connection should be made in accordance with the
manufacturer's instructions and tools should not be used.

i.

If the continuation of supply is interrupted when a cylinder is
changed, it is essential that all appliance taps are turned off
before the change is made.

j.

With bulk storage tanks always ensure that the site is kept
clean and clear of rubbish.  Such vessels are designed to be
filled on site by the gas distributors.

Summary of Contents for CLASSIC SE FF

Page 1: ...iance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers Classic Your Ideal users guide See reverse for Classic installation servicing instructions ...

Page 2: ...le switch having a 3mm 1 8 contact separation in both poles or a plug and socket serving only the boiler and system controls The means of isolation must be accessible to the user after installation Important notes a This appliance must not be operated without the casing correctly fitted and forming an adequate seal b If the boiler is installed in a compartment then the compartment MUST NOT be used...

Page 3: ...the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency Changing gas cylinders a Ensure that the replacement gas cylinder is the correct one for the installation b Extinguish any fire flame or source of...

Page 4: ...l heating or hot water Check on off switch C is in the on position Press overheat thermostat E the boiler should then relight If the fault recurs turn off the boiler and contact the installer Boiler goes through the ignition sequence but will not fire for central heating or hot water Check gas supply try at another gas appliance e g cooker fire If no gas supply then not a boiler fault contact your...

Reviews: