TO RELIGHT THE BOILER

Repeat the procedure from 1-10, detailed in 'To light the boiler'.

LOSS OF SYSTEM WATER PRESSURE

Standard boilers fitted with Classic Sealed System Units only

If the red arrow on the module pressure gauge is set above
zero and the system pressure is seen to fall below this value
over a period of time then a water leak is indicated.  In this
event a CORGI registered installer should be consulted.

DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Ideal Consumer Helpline Tel: 01482 498 660

September 1999

UIN 111 500 A04

Caradon Plumbing Limited,

 P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN.

Telephone:  01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Registered
Office: National Avenue, Kingston upon Hull, HU5 4JN. 

A subsidiary of Caradon plc

The code of practice for the installation,

commissioning & servicing of central heating systems

Caradon Plumbing Limited is a member of the

Benchmark initiative and fully supports the aims of the

programme.  Benchmark has been introduced to

improve the standards of installation and

commissioning of central heating systems in the UK

and to encourage the regular servicing of all central

heating systems to ensure safety and efficiency.

ESCAPE OF GAS

Should a gas leak be suspected, contact your gas supplier
without delay.

Do NOT search for gas leaks with a naked flame.

CLEANING

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

MAINTENANCE

The appliance should be serviced at least once a year by a
CORGI registered installer.

THIS SYMBOL IS YOUR
ASSURANCE OF QUALITY

CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:1994
Quality System accepted by BSI

These appliances are designed for use with
Natural Gas only. They have been tested and
conform with the provisions of BS. 6332 and BS.
5258.

Caradon Plumbing Limited

 pursues a policy of continuing

improvement in the design and performance of its products. The
right is therefore reserved to vary specification without notice.

Natural Gas
appliances are
service listed by
British Gas

LXFF.87/AQ/220
LXRS.87/AQ/221
FF. 87/AP/107
RS.87/AP/108

Summary of Contents for Classic LX RS 230

Page 1: ... 13 Classic LXRS RS 230 260 User s Instructions Wall Mounted Balanced Flue Gas Boilers Natural Gas Models Deluxe models G C Appliance No Classic LX RS 230 41 387 33 Classic LX RS 240 41 387 34 Classic LX RS 250 41 387 35 Classic LX RS 260 41 387 36 CAUTION To avoid the possibility of injury during the installation servicing or cleaning of this appliance care should be taken when handling edges of ...

Page 2: ... longer than 15 seconds before releasing the gas control knob A 8 Switch ON the electricity supply to the boiler Check that all external controls e g room thermostat etc are ON 9 Turn the boiler thermostat knob C to position 6 and the boiler will light Set the boiler thermostat to the desired position 10 Deluxe Model LX Lower the glass fascia after pushing in the sliding catch Standard model Close...

Page 3: ... supply should be left switched ON with the boiler thermostat left in the normal running position View inside controls area LEGEND A Gas control knob B Sightglass C Thermostat knob D Igniter button E Gas inlet cock shown in the OPEN position F Overheat thermostat reset button if fitted Standard Model Deluxe Model BOILER OVERHEAT THERMOSTAT If fitted The boiler is fitted with a safety cutout thermo...

Page 4: ...orts the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency ESCAPE OF GAS Should a gas leak be suspected contact your gas supplier without delay Do NOT search for gas leaks with a naked flame CLEANING ...

Reviews: