Classic FF -
Propane Installation & Servicing
19
INSTALLATION
SIDE FLUE OUTLET
28 FITTING THE SIDE OUTLET PLATES
Note.
If the boiler is fitted closer than 25mm to the side
wall the side outlet plate must be fitted now.
1. Split the side outlet plate into 2 down the split line.
2. Fit the 2 halves of the side outlet plate to the wall,
ensuring they are behind the boiler sealing ring.
1. The boiler is supplied for rear outlet
installation. Remove the blanking plate from
the direction required and use this to blank off
the rear outlet.
2. Lift the boiler onto the wall mounting plate
hooks as shown.
Do not use the burner/controls for lifting.
3. Fit the M8 screw, washer and rectangular
plate to retain the boiler.
1. Fix the mounting plate to the wall with the No.14 x 50mm wood
screws.
2. If the downward routing of pipes is required, then the downward
routing pipe brackets and M8 spacer (supplied in the
Downward Piping Kit) should be fitted to the wall mounting
plate now.
3. Fit the bottom 2 screws to secure the bracket(s) to the wall,
through the wall mounting plate.
4. Check with a spirit level that the plate is vertical.
30 MOUNTING THE BOILER
Notes
1.
Have ready to hand the M8 screw, washer and rectangular plate supplied in the hardware pack.
2.
For downward routing of pipes the M5 spacer (supplied in the Downward Piping Kit) should now be
fitted to the back of the boiler.
Note.
Before fully tightening the M8
screw check, the boiler alignment
using a spirit level and adjust as
necessary with the jacking screw.
29 WALL MOUNTING PLATE
SIDE FLUE OUTLET
Summary of Contents for Classic FF 380 P
Page 1: ......
Page 39: ...Classic FF Propane Installation Servicing 39 NOTES ...