IDEAL CLASSIC

 - 

User’s

7.  POINTS FOR THE BOILER USER

Note.

  

In line with our current warranty policy we would ask that you check through the following guide to identify any 

problems external to the boiler prior to requesting a service engineers visit.  Should the problem be found to be other 

than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is 

not gained by the engineer.

TROUBLESHOOTING

YES

YES

NO HOT WATER

Check the mains power is turned 

on and ensure mode knob (A) is 

in the summer or winter position

Is water coming out of the hot 

water tap when turned on?

NO CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (A) is 

in the winter position

Does the boiler operate and 

provide central heating?

Check the time settings on the 

timer are as you require and 

adjust if necessary

Check the timer is in an “ON” 

position and the room thermostat 

is turned up

NO HOT WATER OR 

CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (A) is 

in the winter position

See boiler “Operation Modes” 

and “Fault Codes” section

Does the boiler have a display 

showing on the front control 

panel?

See boiler “Fault Codes” 

section.  If ‘0’ is displayed then 

contact Ideal Customer Services 

Helpline if your appliance is 

under warranty or a Gas Safe 

Registered Engineer, in IE a 

Registered Gas Installer (RGII), 

if out of warranty

YES

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

NO

See boiler “Operation Modes” 

and “Fault Codes” section.  If “0” 

is displayed then contact a Gas 

Safe Registered Engineer or in 

IE a Registered Gas Installer 

(RGII)

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

Summary of Contents for CLASSIC 24

Page 1: ...nd performance speci cation that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for speci cation and maintenanc...

Page 2: ...lectrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Sup...

Page 3: ...he external controls to OFF The domestic hot water preheat will operate if preheat is enabled shown by indicator light F Boiler Off Set the mode knob A to off The boiler mains power supply must be lef...

Page 4: ...o ignite call your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob C to maximum Must return to original setting once cold spell is over...

Page 5: ...t once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII 6 MECHANICAL 24 HOUR TIMER 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1 5 1 6 1 7 1 8 19 2 0 2 1 2 2 23 24 ON PERIOD...

Page 6: ...ovide central heating Check the time settings on the timer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL...

Page 7: ...for hot water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating mode The boiler is operating in pre heat mode The boiler is operating i...

Page 8: ...on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal Boilers if under warranty or alternatively a Gas Safe Registered Engineer if outside of th...

Reviews: