16
British Gas 40 - 80 RD2 -
Installation & Servicing
INSTALLATION
FLUE OUTLET
Note.
For lengths greater than 600mm see Frame 11.
1.
The boiler turret assembly is factory built for rear flue
installation.
2.
Remove the turret access cover.
3.
Remove the sealing plate from the appropriate side to be
used and refit in the rear outlet.
14 SIDE FLUE ASSEMBLY - Exploded view -
For wall thickness 114mm to 600mm
3.
Flue assembly.
4.
Boiler sealing ring.
5.
Flue extension tube ( with ring).
LEGEND
1.
Terminal.
2.
Weather seal.
4.
Fit the outlet elbow pointing in the desired direction. Rotate
in the bayonet slot and secure with the M4 screw.
5.
Fit the kit extension tube (with ring) to the flue elbow, rotate
in the bayonet slot and secure with the M4 screw.
6.
When cutting the ducts always use the cardboard support
provided.
4
5
3
2
1
Mex
1843
6
10
9
8
7
15 TOP FLUE OUTLET ASSEMBLY - Exploded view
Note.
For lengths greater than 600mm see Frame 11.
1.
The boiler turret assembly is factory built for rear flue
installation.
5
Mex
1844
1
6
3
2
4
7
LEGEND
1.
Terminal.
2.
Weather seal.
3.
Flue assembly.
4.
Boiler sealing ring.
5.
Flue extension tube.
6.
Elbow.
7.
Flue connector.
8.
Turret access cover.
2.
Remove the turret access cover.
3.
Remove the sealing plate from the turret access cover and
refit in the rear outlet.
4.
Fit the outlet flue elbow pointing upwards, rotate in the
bayonet slot and secure with the M4 screw.
5.
Fit the kit extension tube (with no ring) to the flue elbow,
rotate in the bayonet slot and secure with the M4 screw.
6.
When cutting the ducts always use the cardboard support
provided.
6.
Elbow.
7.
Side outlet plate.
8.
Flue connector.
9.
Sealing plate.
10.
Turret access cover.