background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

September  2001

UIN 157 023 A01

The code of practice for the installation,

commissioning & servicing of central heating systems

British Gas Services Limited

 is a member of the Benchmark initiative

and fully supports the aims of the programme.  Benchmark has been

introduced to improve the standards of installation and commissioning of

central heating systems in the UK and to encourage the regular

servicing of all central heating systems to ensure safety and efficiency.

CERTIFIED PRODUCT
Manufactured under a BS EN
ISO 9001:1994 Quality System
accepted by BSI.

British Gas

 pursues a policy of

continuing improvement in the design
and performance of its products. The
right is therefore reserved to vary
specification without notice.

British Gas Services Limited.

 Registered in England, No. 3141243. Registered Office: Millstream,

Maidenhead Road, Windsor, Berkshire SL4 5GD.   British Gas Services Ltd. has made every effort to
ensure that the information contained in this leaflet is accurate. However, not all the information is
within the control of British Gas Services Ltd., and it may have changed since publication. British
Gas Services Ltd. does not accept any liability for changes which occur after publication. No
guarantee takes away any rights you may have at law. Calls to this number may be monitored to
maintain a high level of service and for training purposes.

Priority Helpline 08459 500 400

This boiler is exclusively manufactured for British Gas by Ideal Boilers

Control of water temperature

1.

Adjust the boiler thermostat (B) to give the required temperature
for central heating.

2.

The boiler thermostat automatically switches the main burner

OFF and ON to maintain the selected temperature.

To shut down the boiler

1. For short periods

Set the boiler On/Off knob (B) to OFF.  When heating is
again required, turn the knob to the desired position.

2. For longer periods

Set the boiler On/Off knob (B) to OFF. Switch OFF the
electricity supply.

To relight the boiler

Repeat the procedure 1 - 8, detailed in 'To light the boiler'.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls at a reduced
temperature setting.For longer periods, the entire system should
be drained -  including the domestic water supply.  If the system
includes a frost thermostat then, during cold weather,  the boiler

should be turned OFF at the time switch(es) ONLY. The mains
supply should be left switched ON, with the boiler thermostat left
in the normal running position.

Boiler Overheat Thermostat

The boiler is fitted with a safety 'cutout' thermostat. This will shut
down the boiler in the event of overheating. Should this occur
allow the boiler to cool, press the reset button (E) then relight as
detailed in steps 1-8 in 'To light the boiler'.

If the cutout condition still persists turn off the boiler and consult a
CORGI registered installer.

Loss of system water pressure

Boilers fitted with Sealed System Units only

If the red arrow on the unit pressure gauge is set above zero and
the system pressure is seen to fall below this value over a period
of time then a water leak is indicated.  In this event a CORGI
registered installer should be consulted.
DO NOT OPERATE THE BOILER IF THE PRESSURE HAS

REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Escape of gas

Should a gas leak be suspected, contact your local gas supplier
without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a CORGI
registered installer

.

Approximate flow temperatures for the boiler thermostat settings are:

If you would like this leaflet in an
alternative format such as large
print, Braille or audio cassette
please call us on 0845 7 754 754

If you have impaired hearing
and use a text phone please
call us on 0845 6 040 345

Knob Setting

Flow Temperature

°C

°F

1

54

130

2

60

140

3

66

150

4

71

160

5

77

170

6

82

180