3.4.1  Fan motor repair  

3.4.1.1  Replace fan blade 

To replace the condenser fan, all the steps fro

Chapter 3.4

 must be completed first. 

Remove all screws from the fan grille, and lift the entire fan from the condenser. 

 

Remove all screws from the fan blade and detach it from the motor mount. 

 

Put the new fan back on the motor mount and secure it with the screws. 

 

 

 

Use a thread locker (Loctite)! 

 

 

Summary of Contents for GASTRO A Series

Page 1: ...mment Translated version of original document Language English Copyright 2021 AKE Ausseer K lte und Edelstahltechnik GmbH The contents of this publication may not be reproduced in whole or in part in...

Page 2: ...Single UKW SB BAK L G xx Gastro G xx Salatbar Single Switch BAK L G xx Gastro G xx KL Snack Bakery Gastro HCG xx SnackLine Cool Bakery H xx Gastro HCOE xx Snacky Bistro Bakery Kombi Gastro O xx Snacky...

Page 3: ...2 2 Parts of control unit ST501 9 3 2 3 Condensing unit parts 10 3 3 Repair of the control unit 11 3 3 1 Replacement of controller display 12 3 3 2 Replacement of controller board 12 3 4 Repair of th...

Page 4: ...in any way sent and published in any form 1 1 Release notes Version Created Comments 21A 01 2021 First version of the original description in German 21B 08 2021 Change of document name refrigerated di...

Page 5: ...at can have an impact on the health of persons Failure to observe these safety instructions can lead to serious injuries This symbol with the comment INFORMATION refers to supporting information and p...

Page 6: ...ling refrigerant Chapter 1 8 Chapter 1 9 must be observed and understood 2 2 Repair equipment test equipment material 2 2 1 Tool Screwdriver set slotted cross TORX version Allen key set Spanner set so...

Page 7: ...ck your obligations in accordance with the national WEEE provisions Sorted disposal is mandatory in any case Additional disposal information can be found in the respective operating manual of the appl...

Page 8: ...nents The power supply must be disconnected before all cleaning and service work To do this unplug the unit or disconnect all poles from the power mains 3 2 Overview of components All electrical compo...

Page 9: ...9 4 ZB cable connection RJ45 9 2 Display ST521 X LED transformer not shown Exploded view of control unit ST200F 3 2 2 Parts of control unit ST501 Overview of all spare parts of the control unit ST501...

Page 10: ...of 25 3 2 3 Condensing unit parts Overview of all spare parts of the condensing unit No Description article No Description article 1 1 1 Fan motor 1 1 6 Compressor 1 1 2 Condenser fan 1 1 5 Capacitor...

Page 11: ...trol unit Unplug the power cord from the connection of the controller housing Release the unlocking clip of the connector Remove the locating screws of the controller housing and pull the entire contr...

Page 12: ...ol unit St rk ST501 Controller housing complete St rk ST501 display St rk ST521 display Put the new original replacement display back into the housing secure it with the locating screws and connect it...

Page 13: ...out of the lower tray support Symbolic photo Make sure that the unit is not pulled completely out of the suspension Damage to the condensing unit may occur if it is dropped Lift the condensing unit o...

Page 14: ...denser fan 1 1 7 Refrigerant collector 1 1 3 Power distributor for motor 1 1 8 Condenser 1 1 4 Dryer 1 1 9 Terminal box 1 1 5 Capacitor 1 1 10 Protective grating fan Exploded view condensing unit Depe...

Page 15: ...blade To replace the condenser fan all the steps from Chapter 3 4 must be completed first Remove all screws from the fan grille and lift the entire fan from the condenser Remove all screws from the f...

Page 16: ...grille as shown Remove the necessary cables of the fan motor from the terminal box Terminal box distribution box Terminal box wiring Place the new fan motor in the correct installation position in th...

Page 17: ...evaporator unit The described work steps may differ from your unit Disassemble remove all shelves extendible drawers etc to access the evaporator unit Fold up the protective plate evaporator cover Re...

Page 18: ...de of the fan housing remove the locating screws and dismantle the associated fan guard grille Symbolic photo Inside of fan housing Fan guard grille Remove the defective fan from the inside of the fan...

Page 19: ...remove all cable ties from the cable harness Remove the wiring from the control unit circuit board and pull the entire control cable out of the tubing Remove the sensor from the support plate plastic...

Page 20: ...cable with suitable fastening materials cable ties and connect it according to the valid product specific wiring diagram 3 6 1 3 Room sensor supply air in the air duct special design Depending on the...

Page 21: ...anufacturer for more information See also see chapter 1 5 of the operating manual for the respective unit No Description article 01 12 00 LED light strip 01 13 00 LED light strip 01 14 00 LED driver L...

Page 22: ...he manufacturer for more information See also see chapter 1 5 of the operating manual for the respective unit Use suitable tools to remove all covers housing to access the transformer Disconnect all c...

Page 23: ...ve unit To be able to disassemble the frame heater the device must be freely accessible from all sides In order to remove the frame heater heating lines it must be disconnected from the control board...

Page 24: ...Frame heater stuck on In this variant the frame heater is attached to the frame with adhesive aluminium tape Remove the adhesive tape and detach the defective heating cable If necessary remove all cab...

Page 25: ...hoto After conversion of the unit After the conversion work the unit must be returned to its original condition in order to ensure perfect operation of the unit All steps for commissioning after each...

Reviews: