Subject to technical changes | Valid from January 2021
48
OPERATION – CARE
CALEO HOT/NEUTRAL
03
3.4.7. Filling with water (units with heating climate)
Risk of burns
Switch the unit off and let it cool down for at least 45 minutes before starting any cleaning work.
WARNING
Fill the water bath with hot water every day before starting the unit.
All Caleo Basic models are equipped with steam preparation. The required amount of water for steam generation is transported from
the water tank to the water bath via a feed pump.
The float switch installed in the water bath causes fresh water to be pumped out of the water tank when the minimum water level is
reached.
The water tank has a capacity of 15 litres and must be filled with fresh water daily before starting the unit.
Each unit has a „monitoring system“ which triggers an acoustic warning signal and switches off the steam production if the water level
in the tank falls below the set level (water tank is empty). An error message / fault “H2O” appears on the display.
Filling with cold water extends the heating phase by up to 30 minutes.
NOTE
As soon as the water tank is empty, an acoustic warning signal sounds for 5 seconds. The optical warning “H2O” in the display moves
up and down and draws attention to the necessary filling.
After filling the water tank, the button (3) on the controller display can be used to acknowledge the error message.